Get our free email newsletter

charged device model

Decreased CDM Ratings for ESD-Sensitive Devices in Printed Circuit Boards

Many sources recently have reported that electrical failures to components previously classified as EOS (Electrical Overstress) are instead the result of ESD (Electrostatic Discharge) failures due to charged-board events (CBE) [1,2]. A charged printed circuit board assembly stores substantially more charge than a discrete device as its capacitance is larger. A subsequent discharge of the board assembly results in increased current for that event - versus that of the discrete component. Consequently, a device’s CDM (charged device model) rating is lowered when mounted in a printed circuit board (PCB). In an attempt to get a feel for just how much it is lowered, we conducted CDM stress tests on components in discrete form, and again after insertion into larger and larger sized pc boards. We found that the CDM ratings are lowered dramatically!

Simulating Small Device CDM Using Spice

In earlier articles in this publication we have discussed the charged device model (CDM) testing of small devices. In the first article we demonstrated that the peak current for small devices does not become vanishingly small.1 The commonly held belief of vanishing current for small devices was shown to be an artifact of measuring the current with the 1 GHz oscilloscope2 specified in the JEDEC CDM standard.6 The second article explained various ways to make CDM testing of small devices more reliable with the use of small surrogate packages, or the use of templates to hold the device during testing.3 In this article we will show how insight can be gained into the CDM testing of small devices using a simple three capacitor circuit model.4, 5

CDM Currents for Small Integrated Circuits

Integrated circuits are tested for their robustness to electrostatic discharge (ESD) using the Human Body Model (HBM) and Charged Device Model (CDM) test methods. Circuits which pass 1000 V HBM or 250 to 500 V CDM can be handled with high yield in manufacturing facilities using basic ESD control procedures. [1, 2] HBM is the oldest, best known and most widely used ESD test method, but most ESD factory control experts contend that the vast majority of ESD failures in modern manufacturing lines are better represented by the CDM test method. The CDM test method is intended to reproduce what happens when an integrated circuit becomes charged during handling, and then discharges to a grounded surface.

Digital Sponsors

Become a Sponsor

Discover new products, review technical whitepapers, read the latest compliance news, and check out trending engineering news.

Get our email updates

What's New

- From Our Sponsors -

Sign up for the In Compliance Email Newsletter

Discover new products, review technical whitepapers, read the latest compliance news, and trending engineering news.