IEC 60761-5Establishes specific standard requirements, including technical characteristics and general test conditions and gives examples of acceptable methods for the tritium effluent monitors.
IEC 60768IEC 60768:2009 provides criteria for the design, selection, testing, calibration and functional location of equipment for the monitoring of radioactive substances within plant-process streams during normal operation conditions and anticipated operational occurrences. Is only applicable to(...)
IEC 60770-3This standard specifies methods for:- assessment of the functionality of intelligent transmitters;- testing the operational behaviour, as well as the static and dynamic performance of an intelligent transmitter and methodologies for determining the reliability and diagnostic features used to(...)
IEC 60772Applies to cable penetrations in reactor containments. Covers the engineered safety requirements to be in the design, calculation, fabrication, assembly, testing, installation and maintenance of cable penetrations. Describes the requirements for the design, construction, test and installation(...)
IEC 60775Applies to CAMAC systems as defined in IEC 60516. The generic standard for BASIC includes a real-time enhancement which is necessarily general. This standard defines specific syntax and semantics for use with CAMAC.
IEC 60780Describes successively the general qualification process, the qualification procedures and methods to be used and the associated documentation. Is applicable to electrical equipment of safety systems used in nuclear power plants.
IEC 60794-4-10IEC 60794-4-10:2014 which is a family specification, covers cable construction, test methods and optical, mechanical, environmental and electrical performance requirements for OPGW (optical ground wire) which is used for the protection of electrical power lines against atmospheric discharges(...)
IEC 60825-1Applicable to safety of laser products emitting laser radiation in the wavelength range 180 nm to 1 mm. A laser product may consist of a single laser with or without a separate power supply or may incorporate one or more lasers in a complex optical, electrical, or mechanical system.
IEC 60832-1Gives the essential requirements for insulating sticks for live working for use on a.c. electrical installations. The products designed and manufactured according to this standard contribute to the safety of the users provided they are used by skilled persons, in accordance with safe methods(...)
IEC 60832-2Gives the essential requirements for devices that can be attached onto and removed from the fitting of the insulating sticks for live working, for use on a.c. electrical installations.
IEC 60839-5-1Specifies the general requirements for the performance, reliability and security characteristics of alarm transmission systems. Covers the general requirements for connections providing signalling between an alarm system and an alarm receiving centre.
IEC 60839-5-2Specifies the general requirements for equipment used in alarm transmission systems. Does not specify the equipment used to display the information at the alarm receiving centre or the installation of the equipment.
IEC 60839-5-4Specifies the requirements for alarm transmission systems using dedicated alarm transmission paths which are additional to those specified in IEC 60839-5-1 and IEC 60839-5-2. Covers dedicated connections providing signalling continuity between an alarm system and the presentation of alarm(...)
IEC 60839-5-5Specifies the requirements for digital communicator systems using the public switched telephone network which are additional to those specified in IEC 60839-5-1 and IEC 60839-5-2. Covers switched connections providing event driven signalling between an alarm system and a remote centre.
IEC 60839-5-6Specifies the requirements for voice communicator systems using the public switched telephone network which are additional to those specified in IEC 60839-5-1 and IEC 60839-5-2. Covers switched connections providing event driven signalling between an alarm system and a remote centre.
IEC 60839-7-1Describes the requirements for standard serial data interfaces in alarm transmission systems. Gives an outline of how alarm transmission systems are connected and the various types of serial data interfaces that might be employed.
IEC 60839-7-2Specifies a common application layer protocol (message structure, formats and transmission procedures) to be used at standard interfaces in alarm transmission systems. Should be used at all such interfaces where equipment from one supplier is intended to inter-work with equipment from other(...)
IEC 60839-7-3Specifies the data link layer message structure, formats and transmission procedures which should be used at standard serial data interfaces in alarm transmission systems where the transmission network employed does not offer a standard protocol.
IEC 60839-7-4Specifies the transport layer message structure, formats and transmission procedures to be used at standard interfaces in alarm transmission systems.
IEC 60839-7-5Specifies the requirements for standard interfaces using a two-wire connection employing ISO/IEC 8482 signalling for use between the control and indicating equipment of an alarm system and one or more alarm system transceivers connected to alarm transmission systems.