  • IEC 60904-4:2009 sets the requirements for calibration procedures intended to establish the traceability of photovoltaic reference solar devices to SI units as required by IEC 60904-2. Applies to photovoltaic (PV) reference solar devices that are used to measure the irradiance of natural or(...)
  • IEC 60904-5:2011 describes the preferred method for determining the equivalent cell temperature (ECT) of PV devices (cells, modules and arrays of one type of module), for the purposes of comparing their thermal characteristics, determining NOCT (nominal operating cell temperature) and(...)
  • IEC 60904-7:2008 describes the procedure for correcting the bias error introduced in the testing of a photovoltaic device, caused by the mismatch between the test spectrum and the reference spectrum and by the mismatch between the spectral responses (SR) of the reference cell and of the test(...)
  • Gives guidance for the measurement of the relative spectral response of both linear and non-linear photovoltaic devices.
  • Defines classifications of solar simulators for use in indoor measurements of terrestrial photovoltaic devices; solar simulators are classified as A, B or C for each of the three categories based on criteria of spectral distribution match, irradiance non-uniformity on the test plane and(...)
  • IEC 60904-10:2009 describes procedures used to determine the degree of linearity of any photovoltaic device parameter with respect to a test parameter. It is primarily intended for use by calibration laboratories, module manufacturers and system designers.
  • Gives recommendations on the data to be measured to enable an operator to diagnose developing deviations from normal functioning so as to take corrective action at an early stage.
  • Defines requirements for additional instrumentation to measure coolant parameters, which are of interest when abnormal conditions arise with either one or two phases of coolant or with gas included in the reactor vessel.
  • Defines a modular data-bus system for data acquisition, data processing and control. Gives mechanical, signal, electrical and protocol specifications that are sufficient to assure compatibility between units from different sources of design and production.
  • IEC 60951-1:2009 provides general guidance on the design principles and performance criteria for equipment to measure radiation and fluid (gaseous effluents or liquids) radioactivity levels at nuclear power plants during and after an accident. It specifies the general characteristics, general(...)
  • IEC 60951-2:2009 provides general guidance on the design principles and performance criteria for equipment for continuous off-line monitoring of radioactivity in gaseous effluents and ventilation air used in nuclear power plants for accident and post-accident conditions.
  • IEC 60951-3:2009 provides general guidance on the design principles and performance criteria for equipment for continuous high range area gamma monitoring in nuclear power plants for accident and post-accident conditions.
  • IEC 60951-4:2009 provides general guidance on the design principles and performance criteria for equipment for continuous in-line or on-line monitoring of radioactivity in process stream in nuclear power plants for accident and post-accident conditions.
  • Specifies very accurate testing of steam turbines to obtain the level of performance with minimum measuring uncertainty. Defines uniform rules for preparing and carrying out an evaluation of the acceptance tests.
  • Provides for acceptance tests of steam turbines of various types and capacities with appropriate measuring uncertainty. Only the relevant portion of these rules will apply to any individual case. The resulting measuring uncertainty of the test result is determined by calculating methods(...)
  • This part of IEC 60953, also called "retrofit code" (RC), establishes a supplementary retrofit code for thermal verification tests of retrofitted steam turbines.
  • Considers the functional design criteria for a Safety Parameter Display System (SPDS) giving concise information to aid operating personnel, particularly in abnormal conditions.
  • IEC 60964:2009 provides functional design requirements to be used in the design of the main control room of a nuclear power plant to meet operational and safety requirements. Also provides functional interface requirements which relate to control room staffing, operating procedures, and the(...)
  • IEC 60965:2009 establishes requirements for the supplementary control points provided to enable the operating staff of nuclear power plants to shut down the reactor and maintain the plant in a safe shut-down state in the event that control of the safety functions can no longer be exercised(...)
  • This standard is applicable to equipment for arc welding and allied processes, including power sources and ancillary equipment, for example wire feeders, liquid cooling systems and arc striking and stabilizing devices.