i
Search:
(clear)
IEC 60092-350:2014 provides the general constructional requirements and test methods for use in the manufacture of electric power, control and instrumentation cables with copper conductors intended for fixed electrical systems at voltages up to and including 18/30(36) kV on board ships and(...)
IEC 60282-1:2009+A1:2014 applies to all types of high-voltage current-limiting fuses designed for use outdoors or indoors on alternating current systems of 50 Hz and 60 Hz and of rated voltages exceeding 1 000 V.
IEC 61508-2:2010 applies to any safety-related system, as defined by IEC 61508-1, that contains at least: one electrical, electronic or programmable electronic element; applies to all elements within an E/E/PE safety-related system; specifies how to refine the E/E/PE system safety requirements(...)
IEC 61508-3:2010 applies to any software forming part of a safety-related system or used to develop a safety-related system within the scope of IEC 61508-1 and IEC 61508-2; provides specific requirements applicable to support tools used to develop and configure a safety-related system within(...)
IEC 61508-4:2010 contains the definitions and explanation of terms that are used in parts 1 to 7 of the IEC 61508 series of standards. The definitions are grouped under general headings so that related terms can be understood within the context of each other. However, it should be noted that(...)
IEC 61508-5:2010 provides information on the underlying concepts of risk and the relationship of risk to safety integrity (see Annex A); a number of methods that will enable the safety integrity levels for the E/E/PE safety-related systems to be determined (see Annexes C, D, E, F and G). The(...)
IEC 61508-6:2010 contains information and guidelines on IEC 61508-2 and IEC 61508 3. Annex A gives a brief overview of the requirements of IEC 61508-2 and IEC 61508-3 and sets out the functional steps in their application. Annex B gives an example technique for calculating the probabilities of(...)
IEC 61508-7:2010 contains an overview of various safety techniques and measures relevant to IEC 61508-2 and IEC 61508-3.The references should be considered as basic references to methods and tools or as examples, and may not represent the state of the art.
Applies to substation automation systems and more specifically defines the communication between intelligent electronic devices in the substation and the related system requirements.
EC 61850-6:2009(E) specifies a file format for describing communication-related IED (Intelligent Electronic Device) configurations and IED parameters, communication system configurations, switch yard (function) structures, and the relations between them. The main purpose of this format is to(...)
EC 61850-7-2:2010(E) applies to the ACSI communication for utility automation. The ACSI provides the following abstract communication service interfaces: abstract interface describing communications between a client and a remote server; and abstract interface for fast and reliable system-wide(...)
IEC 61850-7-4:2010(E) specifies the information model of devices and functions generally related to common use regarding applications in systems for power utility automation. It also contains the information model of devices and function-related applications in substations. In particular, it(...)
IEC 61968-13:2008(E) specifies the format and rules for exchanging modelling information based upon the Common Information Model ("CIM") and related to distribution network data. Allows the exchange of instance data in bulk. Thus, the imported network model data should be sufficient to allow(...)
Specifies the information content of a set of message types that can be used to support many of the business functions related to network operations. Typical uses of the message types defined in this part include data acquisition by external systems, fault isolation, fault restoration, trouble(...)
Specifies the information content of a set of message types that can be used to support many of the business functions related to records and asset management. Typical uses of the message types include network extension planning, copying feeder or other network data between systems, network or(...)
Provides a set of guidelines and general infrastructure capabilities required for the application of the EMS-API interface standards. Describes typical integration scenarios where these standards are to be applied and the types of applications to be integrated. Defines a reference model and(...)
IEC 61970-453:2008(E) defines, at an abstract level, the content and exchange mechanisms used for data transmitted between control center components. Includes the general use cases for exchange of graphic schematic display definitions, and guidelines for linking the schematic definitions with(...)
Specifies the format and rules for producing a machine readable form of the Common Information Model (CIM) as specified in the IEC 61970-301 standard. Describes a CIM vocabulary to support the data access facility and associated CIM semantics.
Describes hardware and protocol specifications for local meter data exchange. In such systems, a hand-held unit (HHU) or a unit with equivalent functions is connected to a tariff device or a group of devices.
Specifies the physical layer services and protocols within the Companion Specification for Energy Metering (COSEM) three-layer connection oriented profile for asynchronous data communication.
Specifies the data link layer for connection-oriented, HDLC-based, asynchronous communication profile.
Specifies the transport layers for COSEM communication profiles for use on IPv4 networks. These communication profiles contain a connection-less and a connection-oriented transport layer, providing OSI-style services to the service user COSEM application layer. The connection-less transport(...)
IEC 62501:2009+A1:2014 applies to self-commutated converter valves, for use in a three-phase bridge voltage sourced converter (VSC) for high voltage d.c. power transmission or as part of a back-to-back link. It is restricted to electrical type and production tests.
Contains the glossary of specific terms and definitions used in the context of Substation Automation Systems which are standardized in the various parts of the IEC 61850 series.
Provides a glossary for the volume of work produced as part of the IEC 61970 series of publications. Supplies terms and abbreviations that are either specific to the series, or that require explanation because of the way that they are used.
Specifies the framework for the specification of Component Interface Specifications (CIS) for Energy Management System Application Program Interfaces. A CIS specifies the interfaces that a component (or application) should implement to be able to exchange information with other components (or(...)
Describes a 3 layer data exchange architecture used for communication with large industrial and commercial customer's metering equipment (remote reading for billing purpose). The public switched telephone network (PSTN) is used as a communication medium for this data exchange.
Describes an architectured application layer used for communication with metering equipment. The associated physical medium and lower layer protocols in a collapsed three-layer model are unspecified
Provides all the information specific to the management DLMS server of the protocols described in IEC 62056-31, 62056-41 and 62056-51
Provides an introduction to the remaining parts of the IEC 62351 series, primarily to introduce the reader to various aspects of information security as applied to power system operations. The scope of the IEC 62351 series is information security for power system control operations. Its(...)