  • IEC 61076-2-104
    IEC 61076-2-104:2014 describes circular connectors M8 screw-locking or with nominal diameter 8 mm snap-locking, typically used for industrial process measurement and control. These connectors consist of fixed and free connectors either rewireable or non-rewireable. Male connectors have round(...)
  • IEC 61098
    Defines mechanical and operational characteristics, minimum performance characteristics and general test procedures for personnel monitoring equipment.
  • IEC 61111
    Applicable to electrical insulating matting made of elastomer for use as a floor covering for the electrical protection of workers on electrical installations.
  • IEC 61112
    Applicable to electrical insulating blankets for the protection of workers from accidental contact with live or earthed electrical conductors, apparatus or circuits and avoidance of short circuits on electrical installations.
  • IEC 61140
    Applies to the protection of persons and animals against electric shock. It is intended to give fundamental principles and requirements which are common to electrical installations, systems and equipment or necessary for their co-ordination.
  • IEC 61169-47
    IEC 61169-45:2014, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for type SQMA quick lock RF coaxial connectors.
  • IEC 61169-49
    IEC 61169-49:2014 which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for type SMAA series thread mated coaxial connectors. 
  • IEC 61171
    Applies to equipment intended for transportable or installed use for monitoring, as a function of time, airborne radioactive iodines in the environment of a nuclear facility during normal operations, during anticipated operational occurrences or during accident conditions.
  • IEC 61172
    Applies to transportable or installed equipment for continuous monitoring of radioactive aerosols in the environment for both normal and accident conditions.
  • IEC 61190-1-2
    IEC 61190-1-2:2014-02 specifies general requirements for the characterization and testing of solder pastes used to make high-quality electronic interconnections in electronics assembly. 
  • IEC 61217
    Applies to equipment and data related to the process of teleradiotherapy, including patient image data used in relation with radiotherapy treatment planning systems, radiotherapy simulators, isocentric gamma beam therapy equipment, isocentric medical electron accelerators, and non-isocentric(...)
  • IEC 61219
    Applies to equipment for temporary earthing or earthing and short-circuiting of electrically isolated parts of a.c. installations, the disconnection of which has been verified, for the protection of workers while work is in progress using lance(s) as the earthing or earthing and(...)
  • IEC 61229
    Applies to rigid insulating covers for live working on a.c. installations, including those described in IEC 60743.
  • IEC 61230
    applicable to portable equipment, with or without matching connection points, for temporary earthing or earthing and short-circuiting of electrically isolated or de-energized a.c. and d.c. installations, distribution and transmission networks, whether they are overhead or underground or of low(...)
  • IEC 61234-2
    Describes the test method for determination of hydrolytic stability of moulded thermosets made of room temperature or oven-curing reaction resins when subjected to simultaneous influence of water and high temperature.
  • IEC 61235
    Applies to insulating hollow tubes made of synthetic materials and intended for tools and equipment for work on systems operating at voltages above 1 kV.
  • IEC 61236
    Applies to saddles, stick clamps and their accessories, used for live working. The products designed and manufactured according to this standard contribute to the safety of the users provided they are used by skilled persons, in accordance with safe methods of work and the instructions for use.
  • IEC 61243-2
    This standard is applicable to portable voltage detectors with or without a built-in power source to be used on electrical systems for voltages of 1 kV to 36 kV a.c., and frequencies from 15 Hz to 60 Hz. This part applies only to resistive voltage detectors used in contact with the part to be(...)
  • IEC 61243-3
    Applicable to hand-held two-pole voltage detectors with its accessories (crocodile clips and detachable leads) to be used in contact with parts of electrical systems: - for a.c. voltages not exceeding 1 000 V at nominal frequencies between 16 2/3 Hz and up to 500 Hz, and/or - for d.c. voltages(...)
  • IEC 61243-5
    This standard is applicable to voltage detecting systems that are single-pole and are capacitively-coupled to live parts. They are used to detect the presence or absence of operating voltage on a.c. electrical systems for voltages from 1 kV to 52 kV, and for frequencies from 16 2/3 Hz to 60(...)
  • IEC 61252
    Applies to instruments for measurement of A-frequency- weighted sound exposure resulting from steady, intermittent, fluctuating, irregular, or impulsive sound. Specifies acoustical and electrical performance requirements for personal sound exposure meters of one accuracy grade.
  • IEC 61256
    Relates to assemblies that are used to monitor clothing for radioactive contamination. Applies to monitoring that is performed after the clothing has been washed and prior to re-use to determine its acceptability for re-use.
  • IEC 61275
    Applicable to a portable or transportable photon spectrometry assembly using a high purity germanium (HPGe) detector to survey, in situ, generally at 1 m above ground level, areas in the environment for discrete radionuclides. This standard specifies for such an assembly the general(...)
  • IEC 61285
    Describes the physical requirements for the safe operation of the process analyser measuring system installed in an AH in order to ensure its protection against fire, explosion and health hazards. This standard extends beyond IEC 60079-16 to include houses with Zone 2 interiors and to apply to(...)
  • IEC 61310-1
    Specifies requirements for visual, acoustic and tactile methods of indicating safety-related information, at the human-machine interface and to exposed persons. It specifies a system of colours, safety signs, markings and other warnings, intended for use in the indication of hazardous(...)
  • IEC 61310-2
    General rules on marking for identification of machinery, for safe use related to mechanical and electrical hazards, and for the avoidance of hazards arising from incorrect connections.
  • IEC 61310-3
    Specifies safety-related requirements for actuators, operated by the hand or by other parts of the human body, at the human-machine interface. It gives general requirements for the standard direction of movement for actuators; the arrangement of an actuator in relation to other actuators; the(...)
  • IEC 61318
    Provides elements for product conformity assessment. Critical defects on tools, devices and equipment for live working are not acceptable. Major defects on tools, devices and equipment for live working are likely to result in failure or in a significant reduction of functionality, while minor(...)
  • IEC 61322
    Applies to installed dose equivalent rate meters, warning assemblies and monitors, and covers equipment intended to measure neutron radiation in dose equivalent quantities of energy between thermal and 15 MeV for the purposes of radiation protection.
  • IEC 61340-4-4
    IEC 61340-4-4:2012+A1:2014 specifies requirements for flexible intermediate bulk containers (FIBC) between 0,25 m3 and 3 m3 in volume, intended for use in hazardous explosive atmospheres. The explosive atmosphere may be created by the contents in the FIBC or may exist outside the FIBC.