Safety Standards Library

AJAX progress indicator
  • i

  • IEC 60839-7-11
    Specifies the requirements for standard interfaces between the Public Switched Telephone Network (PSTN) and alarm system transceivers. Specifies a 1 200 baud interface using ITU-T Recommendation V.23.
  • IEC 60839-7-12
    Specifies the requirements for standard interfaces between the alarm system transceivers and transmission network where both form part of a dedicated channel alarm transmission system as defined in IEC 60839-5-4.
  • IEC 60839-7-2
    Specifies a common application layer protocol (message structure, formats and transmission procedures) to be used at standard interfaces in alarm transmission systems. Should be used at all such interfaces where equipment from one supplier is intended to inter-work with equipment from other(...)
  • IEC 60839-7-20
    Specifies the requirements for standard interfaces between the terminal transceiver of an alarm transmission system and the annunciation equipment. Employs signalling in accordance with ITU-T Recommendation V.24/V.28.
  • IEC 60839-7-3
    Specifies the data link layer message structure, formats and transmission procedures which should be used at standard serial data interfaces in alarm transmission systems where the transmission network employed does not offer a standard protocol.
  • IEC 60839-7-4
    Specifies the transport layer message structure, formats and transmission procedures to be used at standard interfaces in alarm transmission systems.
  • IEC 60839-7-5
    Specifies the requirements for standard interfaces using a two-wire connection employing ISO/IEC 8482 signalling for use between the control and indicating equipment of an alarm system and one or more alarm system transceivers connected to alarm transmission systems.
  • IEC 60839-7-6
    Specifies the requirements for standard interfaces employing ITU-T V.24/V.28 signalling for communications between the control and indicating equipment of an alarm system and transmission equipment used for remote communications, where the transmission equipment is general purpose equipment.(...)
  • IEC 60839-7-7
    Specifies the requirements for standard interfaces between the control and indicating equipment (CIE) of an alarm system and an alarm system transceiver where the alarm system transceiver is intended to plug into a standard space inside the CIE of the alarm system.
  • IEC 60846-1
    Specifies the design requirements and the performance characteristics of dose equivalent (rate) meters intended for the determination of ambient dose equivalent (rate) and directional dose equivalent (rate) as defined in ICRU Report 47.
  • IEC 60846-2
    Applies to portable or transportable dose equivalent (rate) meters and/or monitors for the measurement of ambient and/or directional dose equivalent (rate) from external beta, X and gamma radiation during emergency situations.
  • IEC 60855-1
    Applicable to insulating foam-filled tubes and solid rods, of a circular cross-section, made of synthetic materials and intended to be used for the manufacture and construction of tools and equipment for carrying out live work on electrical systems operating at voltages above 1 kV.
  • IEC 60861
    Defines technical requirements for equipment for monitoring of alpha-, beta- or gamma-emitting radionuclides in liquid effluents and surface waters, provides general guidance as to the possible detection capability of such equipment and indicates when and where its uses may be practicable.
  • IEC 60895
    Applicable to conductive clothing, either assembled from component parts or forming a single complete clothing, worn by (electrically) skilled persons during live working (especially bare-hand working) at a nominal power system voltage up to 800 kV a.c. and ±600 kV d.c. It is applicable to(...)
  • IEC 60900
    Applicable to insulated and insulating hand tools used for working live or close to live parts at nominal voltages up to 1 000 V a.c. and 1 500 V d.c. This third edition cancels and replaces the second edition, published in 2004.
  • IEC 60903
    This standard is applicable to: - insulating gloves and mitts which should normally be used in conjunction with leather protector gloves worn over the insulating gloves to provide mechanical protection; - insulating gloves and mitts usable without over-gloves for mechanical protection.
  • IEC 60974-10
    This standard is applicable to equipment for arc welding and allied processes, including power sources and ancillary equipment, for example wire feeders, liquid cooling systems and arc striking and stabilizing devices.
  • IEC 60976
    Applies to medical electron accelerators when used, for therapy purposes, in human medical practice. This standard applies to medical electron accelerators which deliver a radiation beam of either X-radiation or electron radiation with nominal energies in the range 1 MeV to 50 MeV at maximum(...)
  • IEC 60984
    Applies to insulating sleeves for the protection of workers from accidental contact with live electrical conductors, apparatus or circuits.
  • IEC 61000-3-2
    IEC 61000-3-2:2014 deals with the limitation of harmonic currents injected into the public supply system. It specifies limits of harmonic components of the input current which may be produced by equipment tested under specified conditions. It is applicable to electrical and electronic(...)
  • IEC 61005
    Specifies requirements for the performance characteristics of neutron ambient dose equivalent (rate) meters, and prescribes the methods of testing in order to determine compliance with this standard. Specifies general characteristics, general test procedures, radiation characteristics,(...)
  • IEC 61010-2-010
    IEC 61010-2-010:2014 specifies safety requirements for electrically powered laboratory equipment for the heating of materials, where the heating of materials is one of the functions of the equipment.
  • IEC 61010-2-201
    Specifies the complete safety requirements for control equipment (e.g. programmable controller (PLC)), the components of Distributed Control Systems, I/O devices, Human Machine Interface (HMI)).
  • IEC 61017-1
    Applies to portable, transportable or installed assemblies intended to measure environmental air kerma rates from 30 nGy h-1 to 10 µGy h-1 due to X or gamma radiation of energy between 50 keV and 1,5 MeV.
  • IEC 61017-2
    Applies to portable or installed integrating assemblies intended to measure environmental air kerma due to X or gamma radiation of energy between 50 keV and 1,5 MeV by integration of the detector's signal
  • IEC 61018
    Provides basic performance and design requirements for beta and/or photon high-range dose and dose rate measuring instruments used for prompt assessment of radiological emergencies. Specifies the general characteristics, operating characteristics, electrical, mechanical, safety and(...)
  • IEC 61032
    Specifies details and dimensions of test probes intended to verify the protection provided by enclosures with regard to: - protection of persons against access to hazardous parts inside the enclosure; - protection of the equipment inside the enclosure against ingress of solid foreign objects.
  • IEC 61034-1
    Provides details of the test apparatus to be used for measuring smoke emission when electric or optical fibre cables are burnt under defined conditions, for example, a few cables burnt horizontally.
  • IEC 61034-2
    Provides details of the test procedure to be employed for the measurement of the density of smoke emitted from cables burning under defined conditions. It describes the means of preparing and assembling cables for test, the method of burning the cables, and gives recommended requirements for(...)
  • IEC 61057
    Applies to aerial devices (mobile elevating work platforms (MEWP)), with or without the possibility of an additional jib, as a minimum with an insulating upper boom (extending structure) used for live working on the rated voltage, which is between 1 kW r.m.s. and 800 kV r.m.s., at power frequency.

X