  • IEC 60364-8-1
    IEC 60364-8-1:2014 provides additional requirements, measures and recommendations for the design, erection and verification of all types of low-voltage electrical installation including local production and storage of energy for optimizing the overall efficient use of electricity. 
  • IEC 60502-2
    IEC 60502-2:2014 specifies the construction, dimensions and test requirements of power cables with extruded solid insulation from 6 kV up to 30 kV for fixed installations such as distribution networks or industrial installations. 
  • IEC 60528
    Applicable to non-dispersive infra-red analyzers specified for installation either indoors or outdoors and used for the continuous determination of certain aspects of air quality by measuring the gaseous constituents.
  • IEC 60529
    Applies to the classification of degrees of protection provided by enclosures for electrical equipment with a rated voltage not exceeding 72,5 kV.
  • IEC 60532
    Applies to installed dose rate meters, warning assemblies and monitors that are used to prevent or mitigate a minor radioactive release, or minor degradation of fuel, within the nuclear power plants/nuclear facility design basis, and to warn personnel or to ensure their safety during or(...)
  • IEC 60600
    Establishes mandatory requirements and gives a list of characteristics of equipment for grading and sorting radioactive ores in containers at minehead and in opencast workings.
  • IEC 60601-1-12
    Medical electrical equipment – Part 1-12: General requirements for basic safety and essential performance – Collateral Standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment.
  • IEC 60601-1-3
    Applies to X-ray equipment and to subassemblies of such equipment, where radiological images of a human patient are used for diagnosis, planning or guidance of medical procedures. The object of this collateral standard is to establish general requirements for protection against X-radiation in(...)
  • IEC 60601-1-9
    The objective of this collateral standard is to improve the environmental impact for the entire range of medical electrical equipment, taking into account all stages of the product life cycle:
  • IEC 60601-2-1
    IEC 60601-2-1:2009+A1:2014 applies to the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV, used for treatment of patients. This particular standard establishes requirements to be complied with by manufacturers in the design and construction of(...)
  • IEC 60601-2-64
    IEC 60601-2-64:2014 applies to the basic safety and essential performance of Light Ion Beam Medical Electrical equipment, hereafter referred to as ME equipment, used for treatment of patients.
  • IEC 60601-2-68
    IEC 60601-2-68:2014 applies to the basic safety and essential performance of X-ray based image-guided radiotherapy (IGRT) equipment for use with External Beam Equipment (EBE). This particular standard covers safety aspects of kilovoltage and megavoltage X-ray imaging devices in a known(...)
  • IEC 60657
    Summarizes the present position on difference in limits and attitudes towards non-ionizing hazards adopted by a number of different countries, and by the IEC and other international organizations, in standards and recommendations.
  • IEC 60695-1-10
    Provides general guidance on how to reduce to acceptable levels the risk of fire and the potential effects of fires involving electrotechnical products. It also describes the relationship between fire risk and the potential effects of fire, it also emphasises the importance of the scenario(...)
  • IEC 60695-1-11
    Provides guidance for assessing the fire hazard of electrotechnical products and for the resulting development of fire hazard testing as related directly to harm to people, animals or property.
  • IEC 60695-1-30
    Provides guidance for assessing and choosing candidate materials, components or sub-assemblies for making an end-product based upon preselection testing. It describes how preselection provides comparative fire hazard test methods to evaluate the performance of a test specimen and how(...)
  • IEC 60695-1-40
    Provides guidance on the minimization of fire hazard arising from the use of electrical insulating liquids, with respect to: electrotechnical equipment and systems and people, building structures and their contents.
  • IEC 60695-10-2
    Specifies the ball pressure test as a method for evaluating the softening temperature and accelerated material flow under load of polymeric materials and parts of end products in their ability to resist abnormal heat. It is applicable to the materials used in electrotechnical equipment,(...)
  • IEC 60695-11-10
    Specifies small-scale laboratory test procedures intended to compare the burning behaviour of different materials used in electrotechnical products when vertically or horizontally oriented test bar specimens are exposed to a small flame ignition source with a nominal thermal power of 50 W.
  • IEC 60695-11-2
    Gives the requirements for the production and confirmation of a nominal 1 kW, propane/air pre-mixed test flame. This basic safety publication is intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 104 and ISO/IEC Guide 51.
  • IEC 60695-11-20
    Specifies a small-scale laboratory screening procedure for comparing the relative burning behaviour of specimens made from plastics and other non-metallic materials, as well as their resistance to burn-through when exposed to a flame ignition source of 500 W nominal power.
  • IEC 60695-11-3
    Provides detailed requirements for the production of either of two 500 W nominal, pre-mixed type test flames. The approximate overall height of each flame is 125 mm.
  • IEC 60695-11-4
    Provides a description of the apparatus required to produce a 50 W test flame and a description of a calibration procedure to check that the test flame produced meets given requirements.
  • IEC 60695-11-5
    Specifies a needle-flame test to simulate the effect of a small flame which may result from fault conditions, in order to assess by a simulation technique the fire hazard. It is applicable to electrotechnical equipment, its sub-assemblies and components and to solid electrical insulating(...)
  • IEC 60695-2-10
    Specifies the glow-wire apparatus and common test procedure to simulate the effects of thermal stresses which may be produced by heat sources such as glowing elements or overloaded resistors, for short periods, in order to assess the fire hazard by a simulation technique.
  • IEC 60695-2-11
    Specifies the details of the glow-wire test to be applied to end-products for fire hazard testing. For the purpose of this standard, end-product means electrotechnical equipment, its subassemblies, and components.
  • IEC 60695-2-12
    Specifies the details of the glow-wire test to be applied to test specimens of solid electrical insulating materials or other solid materials for flammability testing to determine the glow-wire flammability index (GWFI).
  • IEC 60695-2-13
    Specifies the details of the glow-wire test to be applied to test specimens of solid electrical insulating materials or other solid materials for ignitability testing to determine the glow-wire ignition temperature (GWIT).
  • IEC 60695-4
    The terms and definitions in this standard are applicable to fire tests for electrotechnical products. This basic safety publication is intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 104 and ISO/IEC Guide 51.