  • EN 2794-004:2014
    This European Standard specifies the characteristics of single-pole circuit breakers, temperature compensated with a rated current from 20 A to 25 A, used in aircraft on-board circuits at a temperature between – 55 °C and 125 °C and at an altitude of 15 000 m max. 
  • EN 6059-406
    This European Standard specifies the method and means required for testing the vibration resistance of protection sleeve for electrical cable and cable bundles for aerospace application. It shall be used together with EN 6059-100.
  • EN 6059-504:2014
    Specifies methods of assessing the behavior and temperature increase of cable loom when fitted with protection sleeves or conduits subject to normal and fault currents. It shall be used together with EN 6059-100.
  • EN 6059-601
    This European Standard specifies a method of assessing the behavior of protection sleeves or conduits subject to open and close manipulation for installation, rework and repairs. It shall be used together with EN 6059-100.
  • i

  • IEC 60050-195
    It has the status of a horizontal standard in accordance with IEC Guide 108.
  • IEC 60050-651
    It has the status of a horizontal standard in accordance with IEC Guide 108.
  • IEC 60050-821
    It has the status of a horizontal standard in accordance with IEC Guide 108.
  • IEC 60086-4
    IEC 60086-4:2014 specifies tests and requirements for primary lithium batteries to ensure their safe operation under intended use and reasonably foreseeable misuse.
  • IEC 60099-4
    Applies to non-linear metal-oxide resistor type surge arresters without spark gaps designed to limit voltage surges on a.c. power circuits with Us above 1 kV.
  • IEC 60099-9
    IEC 60099-9:2014 applies to non-linear metal-oxide resistor type surge arresters without spark gaps designed to limit overvoltages in HVDC converter stations of two terminal, multiterminal and back-to-back type up to and including an operating voltage of 1 100 kV. 
  • IEC 60115-2
    IEC 60115-2:2014 is applicable to leaded fixed low-power film resistors for use in electronic equipment. These resistors are typically described according to types (different geometric shapes) and styles (different dimensions) and product technology.
  • IEC 60115-8-1
    IEC 60115-8-1:2014 is applicable to the drafting of detail specifications for fixed surface mount (SMD) low-power film resistors in rectangular chip shape (styles RR) or in cylindrical MELF shape (styles RC) classified to level G, which is defined in IEC 60115-8:2009, 1.5 for general(...)
  • IEC 60204-11
    Applies to the electrical and electronic equipment and systems of machines, including a group of machines working together in a coordinated manner, but excluding higher level system aspects (i.e. communications between systems)
  • IEC 60204-31
    Applies to electrical and electronic equipment, sewing machines, units and systems, designed specifically for professional use in the sewing industry. It is applicable to the electrical equipment or parts of the electrical equipment which operate with nominal supply voltages not exceeding 1(...)
  • IEC 60204-33
    Applies to electrical and electronic equipment associated with semiconductor fabrication equipment for the manufacture, measurement, assembly, and test of semiconductors. It is applicable to the electrical equipment or parts of the electrical equipment that operate with nominal supply voltages(...)
  • IEC 60269-1
    IEC 60269-1:2006+A1:2009+A2:2014 is applicable to fuses incorporating enclosed current-limiting fuse-links with rated breaking capacities of not less than 6 kA, intended for protecting power-frequency a.c. circuits of nominal voltages not exceeding 1 000 V or d.c. circuits of nominal voltages(...)
  • IEC 60287-1-1
    IEC 60287-1-1:2006+A1:2014 Applicable to the conditions of steady-state operation of cables at all alternating voltages, and direct voltages up to 5 kV, buried directly in the ground, in ducts, troughs or in steel pipes, both with and without partial drying-out of the soil, as well as cables in air.
  • IEC 60325
    Lays down standard requirements and gives examples of acceptable methods, and also specifies general characteristics, general test conditions, radiation characteristics, electrical safety, environmental characteristics, and the requirements of the identification certificate for alpha, beta and(...)
  • IEC 60331-1
    Specifies the test apparatus and procedure and gives the performance requirements, including recommended flame application times, for low voltage power cables of rated voltage up to and including 0,6/1,0 kV and control cables with a rated voltage which are required to maintain circuit(...)
  • IEC 60331-11
    Specifies the test apparatus to be used for testing cables required to maintain circuit integrity when subject to fire alone when the test condition is based upon a flame with a controlled heat output corresponding to a temperature of at least 750 °C. Provides the method of verification of the(...)
  • IEC 60331-2
    Specifies the test apparatus and procedure and gives the performance requirements, including recommended flame application times, for low-voltage power cables of rated voltage up to and including 0,6/1,0 kV and control cables with a rated voltage which are required to maintain circuit(...)
  • IEC 60331-21
    Specifies the test procedure and gives the performance requirement, including a recommended flame application time, for cables of rated voltages up to and including 0,6/1,0 kV required to maintain circuit integrity when subjected to fire under specified conditions. Describes the means of(...)
  • IEC 60331-23
    Specifies the test procedure and gives the performance requirement, including a recommended flame application time, for electric data cables required to maintain circuit integrity when subjected to fire under specified conditions. Describes the means of sample preparation, continuity checking(...)
  • IEC 60331-25
    Specifies the test procedure and gives the performance requirement, including a recommended flame application time, for optical fibre cables required to maintain circuit integrity when subjected to fire under specified conditions. Describes the means of sample preparation, continuity checking(...)
  • IEC 60331-3
    Specifies the test apparatus and procedure and gives the performance requirements, including recommended flame application times, for low-voltage power cables of rated voltage up to and including 0,6/1,0 kV, and control cables with a rated voltage which are required to maintain circuit(...)
  • IEC 60332-1-1
    Specifies the test apparatus for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions. The procedure, together with an informative annex of recommended requirements for performance, is(...)
  • IEC 60332-1-2
    Specifies the procedure for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions. The apparatus is given in IEC 60332-1-1.
  • IEC 60332-1-3
    Specifies a test procedure for assessment of falling flaming droplets/ particles when a single vertical electrical insulated conductor or cable, or optical fibre cable, is subjected to defined fire conditions.
  • IEC 60332-2-1
    Specifies the test apparatus for testing the resistance to vertical flame propagation for a single small vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions. The procedure, together with an informative annex of recommended requirements for(...)
  • IEC 60332-2-2
    Specifies the procedure for testing the resistance to vertical flame propagation for a single small vertical electrical insulated conductor or cable, or optical cable, under fire conditions. The apparatus is given in IEC 60332-2-1. This standard gives the procedure for testing small optical(...)