IEC 60050-617:2009 has been published as a consequence of deregulation of the electricity market, it appeared necessary to establish a common glossary with those terms defining actors in the market, interface between actors and the technical or financial terms having a specific meaning in the(...)
It has the status of a horizontal standard in accordance with IEC Guide 108.
It has the status of a horizontal standard in accordance with IEC Guide 108.
IEC 60065:2014 applies to electronic apparatus designed to be fed from the mains, from a supply apparatus, from batteries or from remote power feeding and intended for reception, generation, recording or reproduction of audio, video and associated signals. It also applies to apparatus designed(...)
This standard defines sound pressure and sound intensity measurement methods from which sound power levels of transformers, reactors and their associated cooling devices are determined. The methods are applicable to transformers, reactors and their cooling devices - either fitted to or(...)
IEC 60086-4:2014 specifies tests and requirements for primary lithium batteries to ensure their safe operation under intended use and reasonably foreseeable misuse.
IEC 60092-350:2014 provides the general constructional requirements and test methods for use in the manufacture of electric power, control and instrumentation cables with copper conductors intended for fixed electrical systems at voltages up to and including 18/30(36) kV on board ships and(...)
IEC 60092-360:2014 specifies the requirements for electrical, mechanical and particular characteristics of insulating and sheathing materials intended for use in shipboard and fixed and mobile offshore unit power, control, instrumentation, and telecommunication cables.
Applies to non-linear metal-oxide resistor type surge arresters without spark gaps designed to limit voltage surges on a.c. power circuits with Us above 1 kV.
IEC 60099-9:2014 applies to non-linear metal-oxide resistor type surge arresters without spark gaps designed to limit overvoltages in HVDC converter stations of two terminal, multiterminal and back-to-back type up to and including an operating voltage of 1 100 kV.
IEC 60115-2:2014 is applicable to leaded fixed low-power film resistors for use in electronic equipment. These resistors are typically described according to types (different geometric shapes) and styles (different dimensions) and product technology.
IEC 60115-8-1:2014 is applicable to the drafting of detail specifications for fixed surface mount (SMD) low-power film resistors in rectangular chip shape (styles RR) or in cylindrical MELF shape (styles RC) classified to level G, which is defined in IEC 60115-8:2009, 1.5 for general(...)
Applies to the electrical and electronic equipment and systems of machines, including a group of machines working together in a coordinated manner, but excluding higher level system aspects (i.e. communications between systems)
Applies to electrical and electronic equipment, sewing machines, units and systems, designed specifically for professional use in the sewing industry. It is applicable to the electrical equipment or parts of the electrical equipment which operate with nominal supply voltages not exceeding 1(...)
Applies to electrical and electronic equipment associated with semiconductor fabrication equipment for the manufacture, measurement, assembly, and test of semiconductors. It is applicable to the electrical equipment or parts of the electrical equipment that operate with nominal supply voltages(...)
IEC 60269-1:2006+A1:2009+A2:2014 is applicable to fuses incorporating enclosed current-limiting fuse-links with rated breaking capacities of not less than 6 kA, intended for protecting power-frequency a.c. circuits of nominal voltages not exceeding 1 000 V or d.c. circuits of nominal voltages(...)
IEC 60282-1:2009+A1:2014 applies to all types of high-voltage current-limiting fuses designed for use outdoors or indoors on alternating current systems of 50 Hz and 60 Hz and of rated voltages exceeding 1 000 V.
IEC 60287-1-1:2006+A1:2014 Applicable to the conditions of steady-state operation of cables at all alternating voltages, and direct voltages up to 5 kV, buried directly in the ground, in ducts, troughs or in steel pipes, both with and without partial drying-out of the soil, as well as cables in air.
IEC 60297-3-108:2014 provides dimensions and features for R-type subracks and plug-in units, i.e. ruggedized variants of the mechanical structures of the 482,6 mm (19 in) series, with enhanced vibration and shock resistance and/or improved EMC performance, for use in more harsh environment.
Deals with the definition and the characteristics of control systems. It is not limited to the actual controller tasks but also includes other tasks which may be assigned to a control system, such as sequence control tasks, safety and provision for the actuating energy.
Recommends a limited family of preferred standard coaxial connectors for nuclear laboratory instruments. Applies to coaxial connectors for electrical instruments used in nuclear laboratories.
Lays down standard requirements and gives examples of acceptable methods, and also specifies general characteristics, general test conditions, radiation characteristics, electrical safety, environmental characteristics, and the requirements of the identification certificate for alpha, beta and(...)
Specifies the test apparatus and procedure and gives the performance requirements, including recommended flame application times, for low voltage power cables of rated voltage up to and including 0,6/1,0 kV and control cables with a rated voltage which are required to maintain circuit(...)
Specifies the test apparatus to be used for testing cables required to maintain circuit integrity when subject to fire alone when the test condition is based upon a flame with a controlled heat output corresponding to a temperature of at least 750 °C. Provides the method of verification of the(...)
Specifies the test apparatus and procedure and gives the performance requirements, including recommended flame application times, for low-voltage power cables of rated voltage up to and including 0,6/1,0 kV and control cables with a rated voltage which are required to maintain circuit(...)
Specifies the test procedure and gives the performance requirement, including a recommended flame application time, for cables of rated voltages up to and including 0,6/1,0 kV required to maintain circuit integrity when subjected to fire under specified conditions. Describes the means of(...)
Specifies the test procedure and gives the performance requirement, including a recommended flame application time, for electric data cables required to maintain circuit integrity when subjected to fire under specified conditions. Describes the means of sample preparation, continuity checking(...)
Specifies the test procedure and gives the performance requirement, including a recommended flame application time, for optical fibre cables required to maintain circuit integrity when subjected to fire under specified conditions. Describes the means of sample preparation, continuity checking(...)
Specifies the test apparatus and procedure and gives the performance requirements, including recommended flame application times, for low-voltage power cables of rated voltage up to and including 0,6/1,0 kV, and control cables with a rated voltage which are required to maintain circuit(...)
Specifies the test apparatus for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions. The procedure, together with an informative annex of recommended requirements for performance, is(...)