Standards Library

AJAX progress indicator
  • i

  • IEC 60953-3
    This part of IEC 60953, also called "retrofit code" (RC), establishes a supplementary retrofit code for thermal verification tests of retrofitted steam turbines.
  • IEC 60960
    Considers the functional design criteria for a Safety Parameter Display System (SPDS) giving concise information to aid operating personnel, particularly in abnormal conditions.
  • IEC 60964
    IEC 60964:2009 provides functional design requirements to be used in the design of the main control room of a nuclear power plant to meet operational and safety requirements. Also provides functional interface requirements which relate to control room staffing, operating procedures, and the(...)
  • IEC 60965
    IEC 60965:2009 establishes requirements for the supplementary control points provided to enable the operating staff of nuclear power plants to shut down the reactor and maintain the plant in a safe shut-down state in the event that control of the safety functions can no longer be exercised(...)
  • IEC 60974-10
    This standard is applicable to equipment for arc welding and allied processes, including power sources and ancillary equipment, for example wire feeders, liquid cooling systems and arc striking and stabilizing devices.
  • IEC 60976
    Applies to medical electron accelerators when used, for therapy purposes, in human medical practice. This standard applies to medical electron accelerators which deliver a radiation beam of either X-radiation or electron radiation with nominal energies in the range 1 MeV to 50 MeV at maximum(...)
  • IEC 60984
    Applies to insulating sleeves for the protection of workers from accidental contact with live electrical conductors, apparatus or circuits.
  • IEC 60987
    IEC 60987:2007+A1:2013 Is applicable to computer-system hardware for systems of Class 1 and 2 (as defined by IEC 61513) in nuclear power plants. This new edition reflects recent developments in computer system hardware design, the use of pre-developed hardware and changes in terminology.
  • IEC 60988
    IEC 60988:2009 is applicable to on-site systems used for continuous monitoring of structure-borne sound measured at the reactor coolant pressure boundary of light water reactors for the purpose of detecting loose parts.
  • IEC 61000-3-2
    IEC 61000-3-2:2014 deals with the limitation of harmonic currents injected into the public supply system. It specifies limits of harmonic components of the input current which may be produced by equipment tested under specified conditions. It is applicable to electrical and electronic(...)
  • IEC 61000-4-1
    The object of this part of IEC 61000 is to give applicability assistance to the technical committees of IEC or other bodies, users and manufacturers of electrical and electronic equipment on EMC standards within the IEC 61000-4 series on testing and measurement techniques and to provide(...)
  • IEC 61000-4-10
    IEC 61000-4-10 relates to the immunity requirements of equipment, only under operational conditions, to damped oscillatory magnetic disturbances related to medium voltage and high voltage sub-stations
  • IEC 61000-4-11
    This part of IEC 61000 defines the immunity test methods and range of preferred test levels for electrical and electronic equipment connected to low-voltage power supply networks for voltage dips, short interruptions, and voltage variations. This standard applies to electrical and electronic(...)
  • IEC 61000-4-12
    This part of IEC 61000 relates to the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, to non-repetitive damped oscillatory transients (ring waves) occurring in low-voltage power, control and signal lines supplied by public and(...)
  • IEC 61000-4-13
    IEC 61000-4-13:2002+A1:2009 defines the immunity test methods and range of recommended basic test levels for electrical and electronic equipment with rated current up to 16 A per phase at disturbance frequencies up to and including 2 kHz (for 50 Hz mains) and 2,4 kHz (for 60 Hz mains) for(...)
  • IEC 61000-4-14
    IEC 61000-4-14:1999+A1:2001+A2:2009 applies to electrical and/or electronic equipment that have a rated input current up to 16 A per phase. Aims to establish a reference for evaluating the immunity of electric and/or electronic equipment when subjected to positive and negative low amplitude(...)
  • IEC 61000-4-15
    IEC 61000-4-15:2010 gives a functional and design specification for flicker measuring apparatus intended to indicate the correct flicker perception level for all practical voltage fluctuation waveforms. Information is presented to enable such an instrument to be constructed. A method is given(...)
  • IEC 61000-4-16
    IEC 61000-4-16:1998+A1:2001+A2:2009 Establishes a common and reproducible basis for testing electrical and electronic equipment with the application of common mode disturbances to power supply, control, signal and communication ports. This standard defines test voltage and current waveform,(...)
  • IEC 61000-4-17
    IEC 61000-4-17 defines test methods for immunity to ripple at the d.c. input power port of electrical or electronic equipment. Applies to low-voltage d.c. power ports of equipment supplied by external rectifier systems, or batteries which are being charged. This standard defines test voltage(...)
  • IEC 61000-4-18
    EC 61000-4-18:2006+A1:2010 relates to the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, with regard to: repetitive damped oscillatory waves occurring mainly in power, control and signal cables installed in high voltage and medium(...)
  • IEC 61000-4-19
    IEC 61000-4-19:2014 relates to the immunity requirements and test methods for electrical and electronic equipment to conducted, differential mode disturbances and signalling in the range 2 kHz up to 150 kHz at a.c. power ports.
  • IEC 61000-4-2 
    IEC 61000-4-2:2008 relates to the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges, from operators directly, and from personnel to adjacent objects. It additionally defines ranges of test levels which relate to different(...)
  • IEC 61000-4-20
    IEC 61000-4-20:2010 relates to emission and immunity test methods for electrical and electronic equipment using various types of transverse electromagnetic (TEM) waveguides. These types include open structures (for example, striplines and electromagnetic pulse simulators) and closed structures(...)
  • IEC 61000-4-21
    IEC 61000-4-21:2011 considers tests of immunity and intentional or unintentional emissions for electric and/or electronic equipment and tests of screening effectiveness in reverberation chambers. It establishes the required test procedures for performing such tests. Only radiated phenomena are(...)
  • IEC 61000-4-22
    IEC 61000-4-22:2010 considers immunity tests and emission measurements for electric and/or electronic equipment. Only radiated phenomena are considered. It establishes the required test procedures for using fully anechoic rooms for performing radiated immunity testing and radiated emission(...)
  • IEC 61000-4-23
    IEC 61000-4-23 provides the basic reasons behind HEMP testing and gives a brief description of the most important concepts for shielding element testing. For each test, the following basic information is provided: - theoretical foundation of the test (the test concept); - test set-up; -(...)
  • IEC 61000-4-24
    IEC 61000-4-24 deals with methods for testing protective devices for HEMP conducted disturbance. It primarily covers testing of voltage breakdown and voltage-limiting characteristics but also methods to measure the residual voltage under HEMP conditions for the case of very fast changes of(...)
  • IEC 61000-4-25
    IEC 61000-4-25:2001+A1:2012 describe immunity test levels and related test methods for electrical and electronic equipment and systems exposed to high-altitude electromagnetic pulse (HEMP) environments. Specifications for test equipment and instrumentation test set-up, test procedures,(...)
  • IEC 61000-4-27
    IEC 61000-4-27:2000+A1:2009 considers immunity tests for electric and/or electronic equipment (apparatus and system) in its electromagnetic environment. Only conducted phenomena are considered, including immunity tests for equipment connected to public and industrial networks. Establishes a(...)
  • IEC 61000-4-28
    IEC 61000-4-28:1999+A1:2001+A2:2009 establishes a reference for evaluating the immunity of electric and electronic equipment when subjected to variations of the power frequency. Only conducted phenomena are considered, including immunity tests for equipment connected to public and industrial(...)