Indirect Lightning in Aircraft

The Effects of Induced Currents on Aircraft Electronics

The trouble with aircraft and lightning began shortly after the start of powered flight. Some catastrophic issues occurred and, fortunately, many people survived these events. But research was needed to determine the cause of these problems created by lightning and find potential solutions.

But conducting the needed research also required obtaining data to create these models, and the data at the time required measurements on aircraft while being struck by lightning. Just the thought of flying an aircraft intentionally into a lightning storm to obtain this information requires a stronger constitution than I possess.

Despite these challenges, such measurements were made and enough information was eventually obtained to perform simulations in a laboratory environment. As early as 1940, research began on simulating these effects. By 1967, the danger of lightning strikes to the aircraft had been significantly reduced.

- Partner Content -

The Impact of Solar Superstorms on Engineering Infrastructure and Mitigation

This Application Note discusses the threat of solar superstorms and geomagnetic disturbances to modern infrastructure, highlighting historic events like the Carrington Event. It emphasizes the need for robust engineering solutions, national policies, and advanced protection technologies, such as HEMP filters, to safeguard power grids and critical systems from electromagnetic and geomagnetic risks.

In the 1970s, while working for General Electric as contractors to NASA, Lawrence C. Walko, Franklin A. Fisher, and John Anderson (Andy) Plumer helped develop techniques for performing these simulations, culminating in 1977 with Lightning Protection of Aircraft.1 Plumer founded Lightning Technologies in 1977, which is now part of Element. With Fisher, Andy Plumer wrote DOT/FAA/TC‑22/11, Lightning Protection of Aircraft Handbook.2

Since then, other work has been conducted by the SAE, other researchers, and airframe manufacturers to ensure that the increased sensitivity of electronics is not affected by lightning.

The Impact of Lightning Strikes on Aircraft

How important is this? Can’t we fly around and avoid these lightning strikes? It is said that every aircraft will be hit by a direct lightning strike about once a year. The SAE states that the average probability is one strike every 10,000 flight hours, but a study in a region prone to lightning reports it may be every 1,000 flight hours. This is based on reported events, but other strikes do occur and go unreported. And a few incidents seem to have gone unnoticed by the crew.

As defined by the SAE in ARP5412, an ideal direct lightning strike current has a high current initial spike or stroke in about 5 µs, decaying to a relatively long duration continuing current for less than one second, and followed by another short-duration restrike of fairly high amplitude. The initial stroke is responsible for most of the currents and voltages induced on internal cables and electronics.

Direct lightning attaches itself to the aircraft in various locations, or zones. The ray dome, or nose of the aircraft, often takes the heaviest hits, along with the leading edge of the engines, winglets, and tail. These areas are designated Zone 1. The currents associated with the ray dome have been measured at 200 kA. But the attached lightning strike typically sweeps down the aircraft’s structure as it moves through the air. Thus, the attachment does not remain on the leading edge, and by the time the initial pulse decays, the attachment may have traveled onto the aircraft body or across the wing.

- From Our Sponsors -

The currents associated with the body where the attached lightning hangs on are found to be much lower, possibly in the range of hundreds of amps. This is designated Zone 2. Further division of these zones is given for the location of attachments on the wings and tail, where the attachment may sweep across the wing/tail to the trailing edge, where the hang-on attachment continues until the end of the strike. The area where the current is conducted between these attachment points is designated Zone 3.

For nose cone strikes, the large initial pulse can induce very high fields from the fast rise time and high amplitude of induced currents. Note that this is also the location of the flight deck and electronics bay. Thus, some of the most critical equipment is in the area where the maximum fields are created.

As these currents flow through the airframe, the types and amplitude of currents induced in the internal cables are determined by several factors, including the following:

  • Is the aircraft composite or solid aluminum in which the lightning current has to flow?
  • Are there other impedances in the aircraft structure, such as joints, lack of bonds, corrosion, and so forth?
  • Are the cables routed near doors or windows, or other apertures?
  • Are the cables shielded?
  • Are the cables routed near the nose cone or other initial attachment locations, or are they mainly buried deeper within the body of the airframe?
  • Are the cables long or short?
  • Is the coupling method from the airframe to the cables predominantly inductive (magnetic field‑based due to the induced currents) or capacitive (electric field‑based, due to the voltages induced in the airframe)?

Knowledge of aircraft structure, cable lengths, locations, routing, and so forth is required to understand the test levels and waveforms needed for aircraft certification.

Lightning Induced Current and Voltage Coupling Paths

The currents and voltages associated with these strikes can couple onto aircraft wiring in various ways, and several mechanisms are involved in this transfer of energy. First, there are significant, rapidly‑changing currents in the aircraft’s skin due to the strike, up to 200 kA possibly induced. These high‑level, rapidly‑changing currents generate strong magnetic fields along their paths. Wiring running along the airframe is within the magnetic field’s coupling path, inducing a reverse current in the cable bundle (see Figure 1). For these types of fields, lower‑impedance cables and shields tend to be more sensitive to the coupling mechanism.3

Figure 1: Lightning currents induced into cables
Figure 1: Lightning currents induced into cables

Inducing a current inside the airframe requires a few things: seams and discontinuities in the airframe, and a fast rise time current that is not evenly distributed across the airframe. Apertures and other openings can also couple these fields through the skin or surface of the airframe. In an ideal metal tube with uniform current distribution, there should be no magnetic fields inside the airframe. However, this is not the case for real aircraft. When metal frames and structures, such as aluminum air ducts or cable shields, are in contact with the airframe at various locations across the aircraft, lightning currents can flow through them as well.

Currents will flow around openings, such as windows, doors, and access panels. This can concentrate currents at these locations. Fields can leak through the openings. Thus, cables routed near apertures may experience higher levels of coupling.

Figure 2: Fields coupled into loop created by pigtail shield termination
Figure 2: Fields coupled into loop created by pigtail shield termination

Another effect is the use of shielded cables, which are terminated into pigtails. The pigtail creates a loop due to having some separation from the cables. It is the current in the shield that is concentrated into the pigtail and can induce currents in the core wires by magnetic field coupling.4

When currents flow across seams, joints, and composite fairings, the resulting impedance creates a voltage. Voltages can capacitively couple into cables, inducing voltages, especially on higher impedance lines, such as sensor and data lines. The amount of displacement current, or capacitively coupled current, will depend on the voltage rise and fall times. In the case of lightning, these can be very fast.

Currents having high-frequency and fast rise times in aluminum airframes will induce currents mostly on the aircraft’s surface due to skin effect. But the longer the lightning current hangs on, the longer the wavelength, and the greater the depth of currents appearing in the aircraft. Thus, the induced internal currents will have a long-wave appearance, with slower rise and fall times.

With the increased use of carbon fiber on aircraft (carbon fiber composite, or CFC airframes), the distribution of current is found deeper under the surface and passes through the aircraft below the outer skin. The current waveforms induced in cables from deeper structural currents, such as those from CFC airframes, have longer waveforms, lower impedance, and higher amplitudes than those from surface currents on aluminum airframes.

Modeling Lightning Effects in Design and Testing

But how do we model these effects to use to design and test equipment for aircraft? Andy Plumer states, “Since the 1920s, large numbers of natural lightning current waveforms have been recorded at the earth’s surface. Thus, the characteristic waveforms of natural lightning currents are well-known to science.”5 The typical waveforms used are either double-exponential or damped-sine. The double exponential waveform equation used is:

E = E0(e-αt – e –βt)

Where α and β are time constants used for each waveform, the waveform width is determined by the system’s source and load impedance, namely, whether the source (the airframe) is aluminum or composite fiber. Is the load structural or conductive and, if it is a cable, is it shielded or does it include a shield or ground wire inside the cable bundle? The location of the load will also influence the voltage, E, also known as the transient control test level, ranging from a low of Level 1 to a high of Level 5. If the load is near the airframe, Level 3 is imposed. If it is buried deeper in the structure, Levels 1 or 2 may be imposed. Level 5 is reserved for cables and structures routed in wings (such as flight control actuators, landing gears, and the like), where very intense and concentrated lightning currents may be found.

The pulse previously described often occurs at altitudes from ground level up to about 15,000 feet, and occasionally higher. However, a second type of lightning, cloud-to-cloud events, can occur. These typically occur above 10,000 feet. These strikes are best modeled with multiple burst waveforms, and may be associated with corona events, also known as St. Elmo’s fire. These higher altitude strikes are typically lower in voltage and current, and thus are less damaging and disruptive.

As stated previously, the construction of the airframe and the shielding of the cables will determine the waveforms used. In the case where the aircraft is highly conductive (e.g., aluminum), the main coupling method will be as currents flow across seams or around apertures. Seams will appear as an impedance and can induce voltages into nearby conductors. Apertures can concentrate currents around the opening, which can increase magnetic fields.

In addition, these magnetic fields (aperture fields) will bloom into the airframe more significantly than from solid conductors. These fields can be voltage‑related, capacitively coupled displacement currents. The fields can then be coupled into nearby wire harnesses.

For airframes constructed of CFC, shielding effectiveness of the airframe is reduced, and structure resistance can become problematic. If a lightning strike of 200 kA strikes a CFC airframe having 50 mΩ resistance between attachment points, this can result in an IR voltage of 10 kV. If these bonds are straps or small attachment points such as a rivet, they can be inductive. As a result, the fast risetime of the strike will encounter a higher impedance, increasing the total impedance and the resulting induced voltage. Any electronics referenced to chassis near both ends must deal with the induced field from the current, as well as the IR6 induced voltage from end to end.

Testing for Lightning Effects

To test equipment to these effects, a standardized set of waveforms has been derived. The most common are Waveforms 1 and 4. Both are defined as having a peak obtained in about 6.4 µs and decaying to 50% amplitude at about 70 µs. Waveform 1 is a current waveform representing induced current flowing through cable shields, conduits and the like, which is then coupled into the wiring it contains. Waveform 4 is a voltage waveform that represents the voltage that can appear between the equipment and a reference ground. This voltage can be caused by the lightning current flowing through the resistance of various airframe structures.

Waveform 2 is given as the response of an open circuit to the magnetic field produced by the initial strike of the lightning. It has a very fast rise time, less than 100 ns, and decays quickly to 0 volts in about 6.4 µs. The short‑circuit response to this waveform is defined by the much longer Waveform 1.

Waveform 5 is a long duration, low impedance waveform that is produced by the currents flowing through conductors, airframe structures and other nearby conductors. It is divided into two waveforms, 5A and 5B. Waveform 5A is defined as having a risetime of 40 µs and a decay to 50% at about 120 µS. Waveform 5B has a risetime of 50 µs and a 50% decay in 500 µs. Although rarely used, Waveform 5B is more closely associated with carbon fiber composite airframes.

Waveform 3 is a damped sine oscillatory waveform caused by either the natural resonant frequency of the aircraft, apertures, wiring, or shield terminations. The frequency used is 1 MHz and 10 MHz for cable injection testing, and only 1 MHz for testing individual wires (i.e., pin injection).

Waveform 6, sometimes designated as Waveform 6H, has a 250 ns rise time, and decays to 50% in about 4 µs. It is used specifically for multiple burst tests. The “H” designation and multiple burst testing are associated with intracloud lightning pulse currents. As stated previously, these strikes tend to occur above 10,000 feet and do not contact the ground.

The multiple burst test method uses either Waveform 3 or 6H. The test is performed by applying three individual bursts of 20 pulses within one second and repeated every three seconds for five minutes. All pulses have the same test level. Since these pulses have higher impedances and lower voltages than the single stroke pulses, they have lower energy per pulse. However, the duration of the continual stream of bursts can tax the transient protection being used.

Along with individual pulse applications and multiple burst tests, testing can be applied using several closely spaced pulses called multiple strokes. All except Waveform 6H may be used for multiple stroke testing. Testing is performed with 14 individual strokes within 1.5 seconds. They are randomly spaced during that period, with the first stroke at full level, often using the single stroke test level, followed by 13 strokes at half level.

Conclusion

It is not possible in this short space to provide extensive detail of indirect lightning sources and test parameters. A great deal of information can be found in many documents, including those provided by the SAE. However, the FAA Technical Report is an excellent source of information, with over 500 pages of details, source data, protection information, coupling information, design protection, and so forth. For those not frightened by the math it contains, the physics behind the environment are given in a dedicated chapter, but in a manner that remains readable and helpful to the design engineer. It is well worth keeping in your library.

Endnotes

  1. NASA Reference Publication 1008, Lightning Protection of Aircraft, published April 1977, by Franklin A. Fisher and J. Anderson Plumer.
  2. FAA Technical Report DOT/FAA/TC‑22/11, Lightning Protection of Aircraft Handbook, published November 2022, by Franklin A. Fisher and J. Anderson Plumer.
  3. Ibid., 249-250. Full details of this effect are described throughout the document. Since this is public domain, it is highly encouraged to download and review.
  4. Ibid., 95-96.
  5. Ibid., 28.
  6. Not to be confused with infrared, “IR voltage” is the voltage caused by currents flowing in wire having an inherent resistance in that wire. Since no wire is a perfect conductor, voltage drop always occurs when current is present.