- Advertisement -

Failure Analysis: A Road Map

Although the foundation of a failure analysis is rooted in science, there is also an art to completing one, successfully. The path from problem discovery to problem solution has many bumps and twists along the way. This article will hopefully help guide you on that journey.

Investigative and analytical skills are a must and need to be implemented effectively in order to reach a useful end. Further, time is typically of utmost importance when performing a failure analysis. Knowing how to interpret your results quickly and efficiently will allow you to continue on a forward path. Dead ends will be reached, as well as paths in which the test results offer no apparently useful information; however, one must always bear in mind that a result is truly a result not matter how insignificant it might appear at the time. Being able to eliminate a possible failure mode from the discussion is just as important as identifying the ultimate root cause.

Holistically speaking, an analyst must realize that every failure is unique to the product being investigated; however, experience in performing failure analyses is critical as failure symptoms are very common and your knowledge about them is priceless when trying to diagnose a new failure. Additionally, the gathering of background/historical information about the specimen being investigated is crucial in determining which steps should be taken along your failure analysis path. Knowing the types of questions to ask and what information you should try to obtain is a useful tool.

Within this article we will discuss how to attack printed circuit board (PCB)/printed circuit assembly (PCA) specimens when performing a failure analysis. Specific test methodologies will be discussed with descriptions of the associated test equipment and what an analyst may expect to glean from the results. With the analysis portion complete, we will then discuss report writing and what to do the next time a failed specimen ends up in your hands for analysis!

- Advertisement -


Getting Background Information

From the “source” of the failure (the person(s), department, division, company, etc., that has given you the task of analyzing the failed specimen), you should first obtain the exact goals that are expected from the analysis you are about to perform. Specifically, you should determine if the source has specific questions that need to be answered in order to satisfy the original query. Be sure to document these goals/questions and refer back to them often as you move forward in your failure analysis.

Additionally, you should try and secure as many of the following items as possible:

  • representative failed specimens
  • representative non-failed specimens
  • representative components/materials that comprise the failed specimens
  • representative process chemicals that may have been used in the construction, cleaning, handling, etc. of the failed specimens, and most importantly….

You, as the analyst, need to gather as much information as possible concerning the manufacturing of the product, the exact nature of the failure, the way in which the failure was detected, and the environment in which the failure occurred/was detected.

For the analysis you are about to perform, time will almost always be in short supply. Failures typically result in some kind of “down” condition for your source, and they will be anxious to receive information as soon as you have it. That being said, you must make quick and sound decisions along your path. Do not rush; simply use the information you have at that time to make a scientific decision about where to go next. Sometimes an allotment of failed and non-failed specimens will allow you some leeway in making these decisions as incorrect decisions won’t be costly; however, in most instances, failed specimens will be at a premium, along with representative non-failed specimens of the same date code, lot number, etc., and you will have to make sure you conserve the samples you have and use them to gather as much information as possible. There will even be instances where only a single test can be performed due to its destructive nature. In a situation such as this, you must simply choose the test that will get you the most information and then try and supplement the results in other ways.

With the groundwork set, off we go…

The Initial Examination

Before doing absolutely anything with the failed specimens, find a clean and clutter-free location in which you can spread out all of the supplied specimens and get yourself organized before beginning. At this point, be sure to inspect each test specimen for its proper identification/serialization and record this information for future use when preparing samples for test or for writing your test report.

When ready to begin, use various light sources (natural, fiber optic, IR, etc.), magnifications (via a standard bench microscope or stereomicroscope), and visual enhancement techniques (backlighting, diffused lighting, mirrors, etc.) to perform a detailed visual examination of each and every specimen you have received. Obviously you should concentrate on the specific failure area as identified by your source, but be sure to look around at other similar areas on the same or different specimens depending on what you have received for review. Information in respect to both failed and non-failed areas will be useful later on, and of course, be sure to record and photograph your observations – remember that you will need overview and close-up images to illustrate the situation for your source in the test report.

To get you started, here is a list of questions that you might try to answer with your initial visual examination:

  • Is there visual confirmation of the failure issue?
  • Are there other similar or adjacent areas affected by the failure issue?
  • Do all or some of the specimens exhibit the same failure condition?
  • How many areas are or how much of the area is affected by the failure?
  • In layman’s terms, what does the failure look like (be simple – color, shape, size, etc.)?
  • Is there an industry wide name for the failure issue/condition that you are observing?
  • Do you see anomalies other than those mentioned/described by your source?

With the completion of your initial visual examination, the next step on your failure analysis journey must be determined. Barring in mind your identified failure issue, you must decide whether nondestructive or destructive testing is where you should be heading. In almost every case, you as the analyst should exhaust any and all nondestructive test techniques at your disposal before turning to destructive test techniques. Why? The answer should be obvious; especially if you have yet to visually confirm the failure issue…performing a destructive test too early in the process could damage the true location of the failure and ultimately inhibit your ability to solve the problem at hand…thus, utilize all nondestructive test techniques!

Nondestructive Test Techniques

In addition to the traditional visual examination, various other visual techniques can be used to help see your failed specimen in a different way. Two (2) common techniques are: x-ray examination and Scanning Acoustic Microscopy (SAM). Each of these techniques, in their own way, provide a visual means of understanding things associated with your specimen that you could not see with the naked eye or even a standard stereomicroscope.

The use of x-ray allows you to see inside the “black box”, internal structures that are not visible under normal conditions are now visible. Missing/broken wire bonds, misaligned components, and evidence of counterfeiting are some of the characteristics that can be seen using x-ray. The technique does have inherent limitations however, as the image you see of your specimen is a “thru” shot in which anything in the path of the beam is visualized. With this, some anomalies (such as a BGA solder joint separation at the board interface) might not be seen, while some areas of the failed specimen might not be able to be seen if structures on the opposite side of the board are in the sight line of the region of interest.

As a complement to examination via x-ray, SAM can be used to inspect for anomalies not traditionally seen via x-ray. Of specific interest, SAM is typically used to look for internal anomalies such as delamination, voiding, and/or cracking within a component structure. The scattering of the acoustic signal when air is “struck” at one of these anomalies causes a response in the imaging that allows you to see where and to what extent the internal problem is present. Area or volume calculations can also be performed to better quantify the anomaly.

For these additional examination techniques, the same simple questions that were mentioned above may give more complete answers this time around.

Moving from visual examination techniques to something a bit more quantitative, while assuming that the failure is electrical in nature, an electrical examination should be performed as the next step in the process. This evaluation is an extended qualification of the nature of the failure, as an open circuit will be approached much differently than a shorted circuit, not to mention the difference between a high-resistance and a low-resistance short circuit.

For this examination, focus on the area of interest as specified by your source and obtain electrical characterization information on the failed specimen as well as on the non-failed specimens. In doing this comparison, attempts should also be made to isolate the anomalous conditions if at all possible. And, as always, record everything that you do regardless of whether you currently feel that the result is useless. One must always bear in mind that a result is truly a result not matter how insignificant it might appear at the time.

While performing the electrical examination, here is a list of questions that you might try to answer or obtain information about:

  • Is there an electrical confirmation of the failure issue?
  • Based on your previous experiences, what type of issue would these electrical characteristics cause/create?
  • Is it possible that other areas of the specimen are affected?
  • How many areas are affected by the failure issue?
  • Does the failure condition have a technical name?
  • Do you see anomalies other than those mentioned by your source?

With the main nondestructive test techniques now exhausted and with your failure issue (hopefully) now located, identified, and characterized to the best of your “nondestructive” abilities, it’s time to move on to destructive techniques. Listed in the paragraphs below are various test techniques that inherently cause damage to your test specimen. That being said, you must make wise decisions about the sequence in which the testing will be performed in order to maximize the amount of information that can be gleaned while also minimizing the amount of peripheral damage to the specimen. After all, if you hit a dead end with your initially chosen analysis path, you will need to regroup. Having leftover specimen to test will be critical.

Destructive Test Techniques

With specific information about the failure issue in your back pocket and having had a primary view of the anomaly at hand, decisions must now be made in regard to the specimen’s disposition and exactly in what direction your analysis should be headed. For most PCB/PCA based failure analyses, the path you choose is dependent on where the failure issue is occurring. By that we mean, at what step in the process of the PCA’s construction does the failure issue appear to be manifesting itself. From the evaluations performed above, you should be able to categorize your failure analysis as one of the following – board level or assembly level.

Based on this classification, your first path decision can now be made. The level you have selected will point you towards properties that should be investigated. Table 1 is a list of destructive test techniques and the associated properties that can be found as a result – note that this list is not meant to be all-inclusive but simply a punch list of tests that are typically performed on PCB/PCA type specimens. Choose test techniques that will give results pertinent to the failure issue you are investigating, but don’t forget about any other pieces that could be part of the puzzle you are trying to solve. An analyst should not put on blinders when heading towards a solution. Be aware that sometimes the most influential results are found when performing a test in a specific way. That being said – be creative! The “art” of failure analysis is that it is an ever evolving idea, and a little creativity in selecting your test methodology never hurts.

The paragraphs below provide insight and guidance on each destructive test technique listed in Table 1. The purpose of the specific testing is given along with some questions you might answer or obtain information about.

 

Destructive Test Technique Property
Decapsulation Die inspection
Differential Scanning Calorimetry (DSC) Degree of cure (DTg), glass transition temperature (Tg), melting point (MP)
Dye-n-Pry Analysis Solder Joint Fracture, Solder Joint Strength
Fourier Transform Infrared (FTIR) Spectroscopy Contamination, organic-based
Ion Chromatography (IC) Contamination, ionic-based
Microsection Analysis Board integrity
Scanning Electron Microscopy/Energy Dispersive X-Ray Spectroscopy (SEM/EDS) Contamination, inorganic-based
Solderability Analysis Solderability
Thermal Stress Analysis Board integrity
Thermomechanical Analysis (TMA) Coefficient of thermal expansion (CTE), time to delaminationDecapsulation

 

 


Table 1: The role of various destructive test techniques

This test is more of a sample preparation technique and would be used if the failure issue under investigation is related to the assembly level or, more specifically, the component level. Decapsulation allows for the removal of component encapsulant material such that an internal die structure can be primarily viewed using normal visual techniques or SEM. This inspection can be used as a check of the internal bond wire structures, as well as before a detailed examination of the die’s surface.

When inspecting the internal structures of a decapsulated component, these questions might provide answers or information:

  • Are bond wires present within the component and are they structurally sound?
  • Does the internal die appear to be intact?
  • Is there any evidence of electrostatic discharge (ESD) damage?
  • Could the component and/or the die be a counterfeit?
  • How does the failed component compare to a non-failed (exemplar) component?

Differential Scanning Calorimetry (DSC)

This specific test would typically be conducted for failure issues related to either the board level or the assembly level, given the fact that assembly level failure issues can at times be the result of poor board level construction. Gaining information about a board’s cure status can be extremely useful in determining exactly what has occurred. Specifically, this test method is of great interest if a lack of cure of the board could be contributing to the mode of failure by causing excess expansion of the board during the soldering process. Additionally, if Pb-containing versus Pb-free processing is involved, basic material information about the board’s glass transition temperature (Tg) could be useful. Further, if possible, you should compare the failed sample board’s properties to those of a non-failed board to determine whether or not the specific property of interest is truly an issue.

While performing this DSC Analysis, these questions might provide answers or information:

  • What is the glass transition temperature of the board sample?
  • What was the degree of cure of the board sample?
  • Is it possible or probable that the degree of cure could be causing the failure issue?
  • Given the degree of cure found, what types of problems could this cause/create?
  • Do all of the samples, failed and non-failed, exhibit the same condition?

Dye-n-Pry

This test is typically used for failure issues related to BGA components, although it can be used with some modification for other component types, and would thus be investigated in relation to an assembly level failure. Dye-n-Pry analysis involves the removal of a BGA component in such a way that each individual solder joint can be evaluated for the possibility of an open circuit. Dye penetrant is flowed beneath the component such that the fluid is allowed to “submerge” each individual solder joint ball. Then, once the dye is cured, the component is removed from the board with each of the solder joints is carefully observed. Ultimately, this post-component removal inspection can be used to determine if any open solder joints are indeed present. For solder joints that have some type of failure issue, the dye material will be visible “within” the joint.

When inspecting the Dye-n-Pry test location after component removal, these questions might provide answers or information:

  • Are any fully or partially open solder joints present?
  • For each open solder joint, at which interface – component/solder versus solder/board – has the separation occurred?
  • Is there any evidence of head-in-pillow defect – a defect in which the solder joint does not completely reflow resulting in the solder paste on the board and the solder ball not combining?
  • Is there any evidence of pad cratering – a defect in which the board material has cracked beneath a given surface mount pad?
  • Are there any apparent solder wetting issues?

Fourier Transform Infrared (FTIR) Spectroscopy

This specific test would typically be conducted for failure issues related to the assembly level; specifically, when it is believed that an organic contaminant might be causing visible corrosion or might be contributing to some type of high resistance short. To help determine the exact failure issue, comparing failed and non-failed locations is useful to assist in identifying what organic materials are supposed to be present in comparison to those that are not supposed to be present.

When reviewing the FTIR test results, these questions might provide answers or information:

  • Was an organic contamination/material detected by FTIR?
  • Specifically, what organic material was detected?
  • Is it possible that this organic contamination/material could be causing the failure issue?
  • What type of issue would an organic contamination such as this cause?
  • Is this an isolated issue or are there other areas affected?
  • Do all of the supplied specimens exhibit the same condition?

Ion Chromatography (IC)

This testing would typically be conducted for failure issues related to the assembly level or board level when utilizing no-clean assembly. An analysis via IC would be performed if it is believed that ionic material on the specimen’s surface could be leading to a high resistance short. The testing itself can be performed on a board basis through full extraction or on a localized basis through spot checks at various areas on the specimen’s surface. If the “source” has known ionic cleanliness requirements, this information might be helpful in determining what is occurring in respect to the failure mode at hand. Pass/fail criteria for a test such as IC is not always a definitive way to determine if the specimen is truly clean. A localized concentration of ionic residues would be problematic regardless of the specimens’ overall cleanliness level.

When reviewing the IC test results, these questions might provide answers or information:

  • What types of ionic contamination were detected by IC?
  • Is it possible that the ionic levels detected could be causing the failure issue?
  • What type of issue would the ionic contamination levels detected cause?
  • Do some of the individual ionic levels suggest a potential source for the contaminant?
  • Do both failed and non-failed specimens exhibit the same or similar ionic levels?

Microsection Analysis

This evaluation would typically be conducted for failure issues related to either the board level or the assembly level for examination of internal board anomalies or solder joint related anomalies, respectively. For the analysis, the specimens of interest are diced and mounted in an epoxy resin to allow for cross-sectional examination via metallurgical scope of the board/solder joints in the vertical plane. Evaluation can be performed in a generic sense, simply commenting on what is “seen” or “not seen”, or to an industry standard, such as IPC-A-600 and/or IPC-A-610. Once again, it is best to compare failed regions to non-failed regions while taking many photographs to tell the story of what is occurring – always keep in mind the report that you will need to write upon completion of your analysis!

When evaluating your prepared microsection samples, these might provide answers or information:

  • Are there any internal board issues that could be causing the failure issue?
  • Are there other areas of the specimen that are showing the same anomaly?
  • Do all of the supplied specimens, both failed and non-failed, exhibit the same condition?
  • In layman’s terms, what does the failure look like (be simple – color, shape, size, etc.)?
  • Is there an industry wide name for the failure issue/condition that you are observing?
  • Do you see anomalies other than those mentioned by your source?

Scanning Electron Microscopy/Energy Dispersive X-Ray Spectroscopy (SEM/EDS)

This testing is typically performed for failure issues related to the assembly level but can also be used to help further evaluate possible board level anomalies. SEM/EDS provides both visual and elemental information about the selected area(s) of interest. SEM provides an additional way to visually inspect a sample. The magnifications reached by SEM will be much higher than that which can be obtained by stereomicroscope or metallurgical scope – and don’t forget to take photographs! At the same time, EDS provides elemental information about an observed contaminant or a corrosion product. Typically, these types of materials could be causing a high resistance short and thus need to be evaluated, elementally, in order to determine their composition, and then possibly their origin. Comparing failed and non-failed (or contaminated and non-contaminated) locations is best for determining what elements should be present and which ones should not be present.

When reviewing the SEM/EDS test results, these questions might provide answers or information:

  • Via SEM, did inspection at a higher magnification provide any additional detail to that which was already observed using a stereomicroscope and/or a metallurgical scope?
  • Via EDS, did the identification and quantification of the elemental species present provide any significant information about the observed contaminant/corrosion material?
  • Are there other areas of the specimen that are showing the same anomaly?
  • Do all of the supplied specimens exhibit the same condition, both failed and non-failed?
  • Do you see anomalies other than those mentioned by your source?

Solderability Analysis

This testing would typically be conducted for failure issues related to either the board level or the assembly level. Confirming whether or not a board can pass IPC-J-STD solderability testing is a crucial piece of information when trying to evaluate the cause of a failure, specifically a solder joint failure. When possible, you should attempt to perform this analysis or as many representative samples as possible, bearing in mind that surface mount pads may not solder the same as ones plated through hole.

When performing the solderability test, these questions might provide answers or information:

  • How well did the specimen solder?
  • Did the specimen meet its IPC-J-STD solderability requirement?
  • Could the solderability test result explain or be related to the failure issue?
  • What type of issue would a solderability issue such as this cause?
  • Do all of the supplied specimens exhibit the same condition?

Thermal Stress Analysis

This specific type of testing could be conducted for failure issues related to either the board level or the assembly level. Confirming whether or not a board can withstand repetitive solder reflow cycles is worth a look. After performing the test, microsection specimens are typically prepared and then evaluated to look for anomalies that might be similar to that which has been observed in the failed specimen.

When evaluating the specimens after Thermal Stress Analysis, these questions might provide answers or information:

  • After completion of the Thermal Stress Analysis, were any visual anomalies detected?
  • Were the anomalies found similar to the failure issue observed?
  • Is there an industry wide name for the failure issue/condition that you are observing?
  • Do all of the supplied specimens exhibit the same condition?

Thermomechanical Analysis (TMA)

This specific test would typically be conducted for failure issues related to either the board level or the assembly level. Obtaining information about a board’s expansion properties is a useful piece of information when trying to diagnose the failure issue at hand. Using TMA, thermal expansion properties can be evaluated both in terms of the board’s coefficient of thermal expansion (CTE) and through observation of the board’s behavior when it is held at elevated temperature for an extended period of time, as during solder reflow. For example, if a board delaminates during the reflow process, it would result in a solder joint issue that is being experienced on the assembly level with the cause actually being due to a board level problem.

While performing this TMA Analysis, these questions might provide answers or information:

  • What are the pre- and post- glass transition temperature (Tg) CTE’s for the board sample?
  • What is the “overall” thermal expansion (TE) for the board sample?
  • Are the CTE and TE values found typical given the board’s construction?
  • Can the board sample survive Time-to-Delamination testing?
  • Is it possible/probable that the board’s performance at elevated temperature is causing the failure issue?
  • What types of problems could the thermal expansion properties cause?
  • Do all of the specimens, failed and non-failed, exhibit the same properties?

Ending Your Analysis

Knowing when to stop your analysis is almost as difficult as knowing where to start your analysis. The big difference on this end of the path is that you will know that you have gone far enough when you can answer these questions:

  • Do I have enough information to explain to my source what has happened to the failed sample?
  • Do I have enough information to explain to my source why this has happened to the failed sample?
  • Do I have enough information to answer all of the questions that my source had?
  • Do I have enough information to explain to my source how they can avoid this issue in the future?

The common theme in these questions is “information”. Each and every failure analysis should focus on information – the more the better. This starts from the very beginning, as mentioned above, when you as analyst gather all the appropriate background information so that you can start your failure analysis oriented in the correct direction. From there, you make decisions on how to progress based on the information gathered from each test you select along your path. The various sets of questions listed above for each of the described test methodologies are given to help you gather this information. You must then use the path to collect more and more information until enough is gathered for you to easily and successfully write a test report that your source can understand and use to understand and solve the failure issue at hand.

Writing the Report

Most failure analysis reports are quite detailed and become lengthy due to the many pages of photographs and instrument scans. These items are interesting to look at and do indeed tell a part of the story; however, for most people reading the report, the results given in these items are not understood in the context of simple presentation. That being said, the verbiage that you use as analyst and author is the glue that will bring all of your hard work together. And you truly will be an author at this point, as you need to tell the “story” of your analysis. You need to establish the failure issue at hand and then explain how you went about attacking that problem. The report has to have structure and should flow from section to section. The following is a description of a typical failure analysis report layout:

Section I – The Abstract: When writing a failure analysis report, it is always a good idea to include a statement of work (SOW) to get things started. This SOW can usually be taken directly from your source’s initial contact with you. The SOW will state exactly what the source needs you to determine; for example, “John Smith is experiencing an intermittent open at BGA component location U1 on PCA S/N 12345678.” This type of statement gets the ball rolling in the report and allows you to then follow up with the background information that you have gathered. By including the background information obtained, as discussed earlier in this article, you can paint a picture of how the failure issue at hand has come about. This section will give the history of the specimen as well as any troubleshooting that may have been done on the specimen prior to you coming into possession of it. In the end, the Abstract should be a summary of the information that you were given or obtained prior to the commencement of any testing, nondestructive or destructive.

Section II – The Body: After clearly establishing the failure issue at hand and after presenting the information surrounding the failure itself, it is time to jump right into the testing that you’ve performed. Section II will make up most of your test report and should include sub-sections for each of the test methodologies that you implemented in your analysis, no matter what the result! Within these individual sections, you should describe the samples selected for analysis, the methodology performed, and the results. These results should include any visual observations or numerical values that you’ve come upon that help show the work that you’ve performed. At the same time, unless you feel compelled, there is no real need at this level of the report to describe how a particular single result is related to the failure issue at hand, but you can make some commentary if you’d like – it is, after all, your report. Ultimately, the root cause of the failure issue will likely be drawn from the results of multiple analyses performed. That is why it is ok to simply state results in this section of the report and nothing more – in essence, conclusions are for the Conclusions section! That being said, it is entirely possible that no single test result will mean anything standing alone, and only when all of the results are put together will a true root cause be found.

Section III – Appendix:
With all of your hard work described in words, photographs, tables, and figures in Section II of the report, don’t forget to include any other information that you’ve gathered. Spectra, scans, and the like should all be included in your test report as support for the information that you have provided in the individual test sections. Most of this information might never be looked at by your audience, but it most definitely needs to be there in some form. Provide a list of what you are including and then simply attach everything for reference as needed.

With these three report sections written, the final section ends up becoming the first one in the organization and the most important one to boot! We’ll call it Section “0”…

Section “0” – The Analytical Summary: Given that your audience will include your source and probably your source’s manager or director, you might as well get to the good stuff right away in your report as “some people” aren’t going to want to read all the way to the end! I have found it very useful to put the Analytical Summary right up at the front of the report. This summary should be no more than one to two pages and should highlight the SOW, the Abstract information, the results that you have found throughout your testing and then, most importantly, your conclusions and recommendations. This latter part is clearly and rightfully the most difficult part of your job on this failure analysis. As the analyst, you are responsible for tying everything together and interpreting the results in a way that everyone involved can understand. At times, it is not an easy job; but given experience and knowledge, the path you have taken will lead you directly to the “answer”. For your conclusions and recommendations in this section, here is some helpful advice:

  • Limit your conclusions for the root cause of the failure issue to one or two possible causes.
  • Recommend any possible corrective actions, preventative actions, or repairs that might allow your source to avoid this failure issue/mode in the future.
  • Be sure to specifically answer as many of the questions in the source’s SOW as possible.
  • Depending on the failure issue/mode, compile supporting literature that might be useful to your source.
  • Be as definitive as possible in your statements about the testing you performed and your findings; avoid the words “possibly”, “probably”, “maybe”, etc.

Summary

In this article, a road map for successful failure analysis has been laid out. As you can see, there are many twists and turns that need to be managed, and the amount of information and types of specimens you are given by your source will have a profound effect on what exactly it is you are able to accomplish as well as how well you are able to accomplish it. Sometimes a failure mode will not be found, sometimes the evidence of the failure will not be found in a lab setting, and sometimes all of the evidence of the failure is gone at the time of the analysis. Even in situations such as these, useful information can still be found if searched for in the appropriate manner, and conclusions can be drawn based on results obtained from “similar” specimens. Like a police investigation, PCB/PCA failure analysis can be done “by the book” and when that happens, good things usually result.

 

author_sellers-keith Keith Sellers
the Managing Scientist at Trace Laboratories, Inc.’s facility in Hunt Valley, MD (ksellers@tracelabs.com), has been with Trace since 1999 and holds a bachelor’s degree in Chemical Engineering from the University of Delaware. Keith’s primary work is in the areas of contamination and root cause failure analysis with recent work focused on Pb-free alternatives, tin whiskers, ionic cleanliness, counterfeit components, and related reliability issues.

Sign up for the In Compliance Email Newsletter

Discover new products, review technical whitepapers, read the latest compliance news, and trending engineering news.

Exit mobile version