Low power, license-exempt FM transmitters are used in vehicles to transmit a weak signal onto a vacant channel in the FM Broadcast Band (88-108 MHz) for the purpose of receiving Sirius-XM broadcasts on the vehicle’s FM Radio. The only method for determining compliance of these transmitters according to the FCC Rules and Regulations is to measure the field strength from the transmitter installed in three typical vehicles. This article describes an alternative method for determining compliance by measuring conducted RF power output and using a transfer function derived by measuring the radiated field strength from transmitters installed in a number of vehicles.

Compliance can then be determined by applying the empirically derived transfer function to the conducted power and comparing the result to the FCC limit.1 This article also shows the validity of using a proposed tabletop measurement procedure which will achieve the same result for the fundamental emissions but which could also be used for out-of-band and spurious emissions.


Introduction

A low power transmitter may be operated without an individual license, provided it is certified to comply with Section 15.239 of the FCC Rules and Regulations. For these devices, the FCC field strength limit is 250 microvolts per meter at a 3 meter measurement distance. Typically, field strength measurements are made on a tabletop at an open area test site (OATS) or other approved facility. However, since there is uncertainty as to the validity of tabletop measurements for certain types of FM transmitters, and since radiated emissions may be significantly attenuated when the transmitter is installed in a vehicle, the FCC requires measurements to be made at a minimum of three installations (vehicles) that can be demonstrated to be representative of typical installation sites.2 In other words, compliance is determined by making “in situ” measurements on three typical vehicles. However, performing these in situ measurements is a difficult, expensive, and time consuming process. Furthermore, the vehicle-to-vehicle variations which are inherent in these types of measurements make them poorly suited in terms of their ability to show compliance to FCC limits. Yet this is the only procedure currently permitted by the FCC. This article analyzes certification results for multiple products which have been tested at accredited labs over the past two years and for which the radiated data can be found on the FCC OET website. It compares those results with conducted RF power measurements for the same devices which were made separately, but also at accredited labs. As a result of the analysis, a transfer function value which takes the associated standard deviation into account is proposed. Additionally, measurements from a proposed tabletop method are also shown to be valid for the purposes of showing compliance to FCC limits.

- Partner Content -

Three Vibration/Balancing Solutions for the Aviation Industry

This paper provides a quick overview of aerospace engine testing solutions for engine vibration/balancing as well as signal conditioning technology from MTI instruments.


Derivation of Transfer Function

For an isotropic radiator, the equation that defines the relationship between conducted power in dBm and radiated field strength in dBuV/m for frequencies less than 1,000 MHz is:

1207 F2 eq1    (1)

where E0 is the electric field strength, D is the reference measurement distance, and the value of 109.5 includes a factor of 4.7 dB to account for reflections from the ground plane.

To the extent that the actual measured field strength is lower than the theoretical value, it means that additional losses are present which are not accounted for in the equation. These losses can be due to shielding provided by the vehicle itself, by non-isotropic radiation from the radiator, or by other factors.

To account for these variations when analyzing empirical measurements, a correction factor (CF) can be added into the equation. If a statistically significant number of measurements are made, and if the variations are random, then the CF measurements may be expected to form a normal distribution around the mean. For the case where the measurement distance is 3 meters and with the term for the CF added, Equation 1 can be modified to the following:

- From Our Sponsors -

1207 F2 eq2    (2)

And combining like terms:

1207 F2 eq3    (3)

Now rearranging to put the equation into the familiar form of a transfer function (Output (dB) – Input (dB)):

1207 F2 eq4   (4)

This can be visualized as in Figure 1.

1207 F2 fig1

Figure 1: Relating conducted power to field strength using a transfer function

 

From Equation 4 it can be seen that the correction factor is inversely related to the transfer function (TF) with an offset of 100 dB. Once the TF is determined, it can be used for the purposes of determining a conducted power limit. By rearranging Equation 4 and substituting the FCC part 15.239 limit at FM frequencies for the output, the following equation results:

1207 F2 eq5   (5)

Or if using a correction factor instead:

1207 F2 eq6   (6)

From these equations, it can be seen that a higher TF yields a lower conducted power limit, and a higher CF yields a higher conducted power limit.

As mentioned previously, for in situ measurements of FM transmitters, a high CF means that either the vehicle body provides high attenuation or the radiation pattern is non-isotropic such that the E field measured at the receive antenna is lower than it would be if the pattern were isotropic. Of course, it is also possible that a non-isotropic radiator can increase the gain in the direction of the receive antenna as well. Because of the variability of vehicle shielding and the potential for non-isotropic radiation, in situ measurements of FM transmitters have an inherently high degree of variability.


Measurement Data

The initial arrangement used for measuring radiated field strength emissions from transmitters installed in a vehicle is shown in Figure 2. The general procedures for measuring radiated emissions in situ are contained in Clause 6.12 of C63.10-20094. For certification of the SiriusXM Satellite Radio FM transmitters subject to 47 CFR 15.239, measurements were made of transmitters installed on three vehicles and at three frequencies in the high, low, and mid-band of 88-108 MHz. Currently, tabletop emissions measurements are also being requested by the FCC in addition to the in situ measurements. Sirius XM Satellite Radio Inc, has received certifications for eight products with FM transmitters since August of 2009. The data for these certifications was taken by four different accredited test labs in Virginia, Maryland, Georgia and Florida. All of the in situ and tabletop data in this article was taken from the certification data and can be found on the FCC Office of Engineering and Technology website. After being certified, conducted FM power measurements were made at accredited labs using the same products at the same FM frequencies which were used for the certifications. Since many of the in situ measurements were made at an OATS, only frequencies which were relatively free of strong ambient signals could be used. Thus, in some cases, different frequencies were used for different products.

1207 F2 fig2

Figure 2: Top view of radiated emissions test setup for initial measurements using a turntable

 

Since in situ measurements have high variability, for the purposes of finding the appropriate TF and the associated conducted power limit it was thought that a useful approach might be to minimize the effects of that variation by looking at only the worst case measurements. Worst case is defined as those measurements which yielded the highest TF, because those measurements correspond to the lowest conducted power limits. The results from the frequency and vehicle combinations that met those criteria are plotted in the histogram in Figure 3 .

1207 F2 fig3

Figure 3: Histogram using worst case in situ measurements

 

Note from this plot that ‘Product E’ appears to be an outlier. Initially, it was suspected that the data for that product could be in error, so TF averages and standard deviations were calculated both with and without the data from that product included. Using Equation 5, it can be seen that the average TF values of 69.4 (with Product E) and 70.9 (without Product E) would correspond to conducted power level limits of -21.4 dBm and -22.9 dBm respectively. The standard deviation (SD) was 5.2 and 3.2 respectively for those measurements.

From statistics, it is known that for a normal distribution, approximately 68.3% of the values lie within ±1 SD of the mean, approximately 95.4% of the values lie within ± 2 SD of the mean, and approximately 99.7% of the values lie within ± 3 SD of the mean. If we assume that the Product E measurements were not part of the normal distribution, then the mean is 70.9 and adding 3 SD’s (3 x 3.2) yields a TF limit of 80.5, which corresponds to a conducted power limit of -32.5 dBm. If only 2 SD’s are used, then the TF limit is 77.3, which corresponds to a conducted power limit of -29.3 dBm.

It is instructive here to compare these limits with the actual measured conducted power for those certificated devices. For the eight products measured, the conducted power average, minimum, and maximum, are shown in Table 1.

Average – 28.9 dBm
Minimum measured conducted power – 33.1 dBm
Maximum measured conducted power – 26.1 dBm

Table 1: Conducted average, minimum, and maximum power

From the data in Table 1 it can be seen that if the conducted power limit of -29.3 dBm is used, based on worst case measurements with Product E results removed, using 2 SD’s from the mean and assuming that the distribution is truly normal, then about half of the products that have previously been certified would not pass.

A plot of conducted power levels for the eight products that are the subject of this investigation makes it easy to see that that limit would not be valid (See Figure 4).

1207 F2 fig4

Figure 4: Plot of conducted output power for eight products

Yet as shown in Figure 5, those same products when tested in situ, despite the wide variation, all fall below the FCC limit for radiated emissions.

1207 F2 fig5

Figure 5: In situ radiated emission levels for same eight products

 

And tabletop emissions, measured as per the proposed new ANSI C63.10 procedure, pass as well, but with a tighter distribution (See Figure 6.)

1207 F2 fig6

Figure 6: Tabletop radiated emissions for same eight products

A complete table of measured conducted power is shown in Table 2, along with all in situ data and the associated transfer function and correction factor values.

1207 F2 table2

Table 2: Conducted power, In-Situ data, CF, and TF

 

Using All In Situ Measurements

When all measurements are used instead of worst case only, the range of measurement values increases as expected. As previously mentioned, this likely reflects the fact that some vehicles provide significantly more attenuation than others or that the radiation from within the vehicle structures is not isotropic.

Note too that when all measurements are used, it can be seen that the Product E measurements are encompassed by the wider distribution and, in fact, seem to be legitimate values in what appears to be a normal distribution.

The in situ measurements, which represent eight products, measured at three frequencies and in three vehicles, are plotted in the histogram in Figure 7.

1207 F2 fig7

Figure 7: Histogram using all in situ measurements

The average TF value is 66.5 without Product E and 65.4 with Product E. The standard deviation (SD) is 5.3 and 5.9 respectively for those measurements. Since Product E appears to be part of the normal distribution, it does not make sense to remove it from the data set, so it is believed that a conducted limit should only be calculated with it included. Thus, with Product E included and using the same formulas and calculations as described above, if 2 SD’s are used then the TF mean is 65.4 and the associated conducted power limit is -29.2 dBm.


Using Tabletop Measurements

The arrangement used for making tabletop measurements of radiated emissions from a device which directly injects an FM signal into a vehicle’s wiring system through the CLA socket is shown in Figure 8. The proposed method in fact is the same method that was used to collect the tabletop data for the certifications that are described in this article. All of the products utilized a method of directly injecting the FM signal into the vehicle wiring system through the CLA socket. Thus the procedure described in the ANSI draft revision for those types of transmitters was followed as closely as was possible by all of the test labs.

1207 F2 fig8 sm

Figure 8: Tabletop arrangement for radiated emissions measurements
click image for larger version

The transfer function and various other equations described above for in situ measurements can also be applied to tabletop measurements. However, it can be seen from the data that, for these measurements, the distribution is tighter and the mean is higher. This likely reflects the fact that there is no opportunity for vehicle shielding and thus less opportunity for a higher CF (lower TF).

The certification data for eight products, measured at three frequencies, is represented in the histogram in Figure 9. The average TF value is 71.8 and the SD is 2.6. Using the same formulas and calculations as described above, if 2 SD’s are used then the TF value is 77 and the associated conducted power limit ius -29.0 dBm.

1207 F2 fig9

Figure 9: Histogram of all tabletop measurements

 

A complete set of radiated tabletop measurements, with the associated transfer functions, is shown in Table 3.

1207 F2 table3

Table 3: Complete table of radiated tabletop measurements with associated transfer functions

 

A Comparison of All In Situ and Tabletop Measurements

When all of the data is overlaid on one plot, as in Figure 10, it can be seen that in situ measurements have the widest variation. Worst case in situ measurements have a slightly smaller SD and are distributed nearer to the highest TF values, but can still include outliers. Tabletop measurements have the smallest SD and are distributed most closely to the highest TF values.

1207 F2 fig10

Figure 10: Histogram of all measurements in situ and tabletop

Summary

A summary of the measurements, with transfer functions and associated conducted power limits for 1, 2 and 3 standard deviations, is shown in Table 4.

1207 F2 table4

Table 4: Summary of all test measurements

Previously, it was noted that, for a normal distribution, approximately 95.4% of the values lie within ± 2 SD of the mean. From the histograms, it does appear that the data is distributed normally about the mean. If this supposition is accepted, then a conducted power limit based on the TF calculated using the tabletop method plus 2 SD’s would mean that 95.4% of the products which meet the conducted limit would also pass on the tabletop. For those products which are outside of the 95.4%, only half would be on the high side of the distribution and the other half would be on the low side of the distribution. Further, a diminishing percentage of those products would reach even 1 additional SD of 2.6 dB.

Thus, a transfer function value of 77 is proposed for the purpose of determining radiated emissions levels from conducted power levels at FM frequencies, yielding a conducted power limit of -29 dBm for the fundamental emissions. Further, it is proposed that the tabletop method, as described herein and in the ANSI C63.10 publication scheduled for release in 2012, be used to determine compliance of the out-of-band and spurious emissions to FCC limits so that in situ measurements are no longer required.

favicon

Notes

  1. This procedure was developed in conjunction with the work of the Wireless Working Group of Subcommittee 1 of the American Standards Committee on Electromagnetic Compatibility, C63®. The procedure is to be incorporated into C64.10-20xx – American National Standard for Testing Unlicensed Wireless Devices.
  2. See 47 CFR 15.31(d).
  3. Guidelines for Compliance Testing of Unlicensed National Information Infrastructure (U-NII) Devices – Part 15, Subpart E.
  4. The American National Standard for Testing Unlicensed Wireless Devices is available from the IEEE website at https://www.ieee.org/membership-catalog/index.html?N=0.
author obrien-tom TOM O’BRIEN
has worked on RF and EMC related issues for over 15 years.  He worked for the Florida Atlantic University EMI lab while in college, and continued to work on RF and EMC related projects while at Motorola.  He has recently participated in ANSI standards development activities, and he is currently employed by Sirius XM Satellite Radio where he continues to address a variety of SW Test and certification issues. 
author tenzil-jean JEAN EDNER TEZIL
holds a BA in electrical engineering and is currently pursuing a master in bioengineering at Florida Atlantic University. Since 2010, he has contributed valuable efforts in SW test at Sirius XM Satellite Radio and has been part of the resource team for occupied bandwidth and NSA measurements.  Always excited by opportunities to learn, he recently joined the Advanced Compliance Solutions where he contributes his support in compliance certification testing.
author murad-syed SYED SHAKIL MURAD
holds a BA in Electrical Engineering from Florida Atlantic University. He is employed by Sirius XM Satellite Radio as a software test engineer and part of the resource team for occupied bandwidth testing and NSA measurements. He is also employed by Advanced Compliance Solutions where he performs compliance certification testing.

 

 

Related Articles

Digital Sponsors

Become a Sponsor

Discover new products, review technical whitepapers, read the latest compliance news, and check out trending engineering news.

Get our email updates

What's New

- From Our Sponsors -

Sign up for the In Compliance Email Newsletter

Discover new products, review technical whitepapers, read the latest compliance news, and trending engineering news.