Transmission Line Reflections at a Resistive Load

Foundations

Consider a transmission line of length L driven by a constant voltage source VG with a source resistance RG, and terminated by a resistive load RL, as shown in Figure 1. ZC is the characteristic impedance of the transmission line and T is the time it takes for the voltage wave to travel from the source to the load.

Figure 1: Transmission line driven by a constant source and terminated by a resistive load

 

- Partner Content -

A Dash of Maxwell’s: A Maxwell’s Equations Primer – Part Two

Maxwell’s Equations are eloquently simple yet excruciatingly complex. Their first statement by James Clerk Maxwell in 1864 heralded the beginning of the age of radio and, one could argue, the age of modern electronics.

When the switch closes at t = 0 a forward voltage wave, V +, originates at z = 0 and travels toward the load. This is shown in Figure 2.

Figure 2: Forward voltage wave originates at the source and travels toward the load

 

The value of this voltage is

 (1)

As this wave travels along the transmission line, the voltage along the line changes from 0 to V + and remains at that value (for now). At the time T (about 18 ns for a 12 ft RG58 cable) the voltage wave reaches the load and sets up a reflection, V . This is shown in Figure 3(a).

- From Our Sponsors -
Figure 3: Forward wave arrives at the load (a) incident and reflected voltages (b) total voltage

 

The reflected voltage, V , is related to the incident voltage, V +, by

 (2)

where ΓL is the load reflection coefficient:

1701_ece_eq3_3 (3)

The total voltage at the load is the sum of the incident and reflected voltages

 (4)

The reflected voltage wave, V , now travels back to the source, as shown in Figure 3(b). As this wave travels back to the source, the voltage along the line changes from V + to V + + V . This wave reaches the source at the time 2T and sets up another reflection V -+. This is shown in Figure 4(a).

Figure 4: Reflected wave arrives at the source (a) incident, reflected and re-reflected voltages (b) total voltage

 

The voltage reflected at the source, V -+, is related to the incident voltage,V , by

1701_ece_eq5_3 (5)

1701_ece_eq6_3 (6)

where ΓS is the source reflection coefficient:

The total voltage at the source is now

 (7)

The voltage wave, V -+ now travels forward to the load, as shown in Figure 4(b).

If the source is matched to the transmission line, i.e., R= ZC then the reflection coefficient at the source is zero and therefore there is no reflection at the source. Then the total voltage at the source upon the arrival of the reflected voltage is

1701_ece_eq8_3 (8)

and the reflection process terminates.

Verification

The experimental setup and the circuit model for reflection measurements is shown in Figure 5.

Figure 5: Experimental setup for the load reflection measurements

 

Its circuit model is shown in Figure 6.

Figure 6: Circuit model for the reflection measurements

 

A 2 Vpp (open-circuit voltage) pulse signal was sent from the function generator along the 12 ft coaxial cable (RG58) to the resistive load. The voltages at the source (VS) and at the load (VL) were measured using the oscilloscope probes. Four cases of the load values were considered as shown in Figure 5.

Calculations for each case were performed and are summarized in Table 1. The measurement results are shown in Figure 7.

RL = ∞
Figure 7(a)

RL = 22Ω
Figure 7(b)

RL = 47Ω
Figure 7(c)

RL = 47Ω
Figure 7(d)

Initial voltage at the source,
V+ , z = 0, t = 0

1V

1V

1V

1V

Load reflection coefficient, ΓL

1

-0.39

-0.03

0.624

Voltage reflected at the load,
V , z = L, t = T

1V

-0.39V

-0.03V

0.624V

Total voltage at the load, V+ +
V , z = L, t = T

2V

0.61V

0.97V

1.624V

Total voltage at the source, V+ +
V , z = 0, t = 2T

2V

0.61V

0.97V

1.624V

Table 1: Calculated values

Figure 7: Measurement results

The calculated and measured values, shown in Table 1, closely match, verifying the concept of the transmission line reflections.

Related Articles

Digital Sponsors

Become a Sponsor

Discover new products, review technical whitepapers, read the latest compliance news, and check out trending engineering news.

Get our email updates

What's New

- From Our Sponsors -

Sign up for the In Compliance Email Newsletter

Discover new products, review technical whitepapers, read the latest compliance news, and trending engineering news.